⚡ Contactor Control Wiring: START, STOP & Self-Holding Circuit Explained! 🔧

Do you know how a contactor remains energized even after releasing the START push button? 🤔

The answer is Self-Holding (Seal-in) Circuit!

In this practical electrical guide, you'll learn:

🔹 STOP Push Button (NC): Interrupts the control circuit to switch OFF the contactor.

🔹 START Push Button (NO): Energizes the contactor coil when pressed.

🔹 Contactor Coil (A1–A2): Creates the magnetic force required to operate the contactor.

🔹 Auxiliary Contact (13–14 NO): Provides the self-holding path to keep the coil energized after releasing START.

🔹 Main Contacts: Connect or disconnect the power supply to the motor or other load.

💡 How does it work?

1️⃣ Press START → Contactor coil energizes.
2️⃣ Auxiliary NO contact closes → The circuit holds itself ON.
3️⃣ Release START → Contactor remains energized.
4️⃣ Press STOP → The control circuit opens and the contactor switches OFF.

📌 Important: Always verify the actual terminal markings and manufacturer’s wiring diagram before making connections. In a typical circuit, terminals 13–14 are NO, while 21–22 are NC—the terminal designations shown in the diagram should be checked carefully.

👇 Quiz for Electrical Engineers: What is the purpose of the auxiliary contact in a self-holding circuit?

Share your answer in the comments!

09/14/2026
09/13/2026

🔌 Modbus RTU vs Modbus TCP — What’s the difference?

Modbus RTU uses serial RS-485 communication, while Modbus TCP uses Ethernet/TCP-IP. Understanding their speed, topology, distance, and application differences helps you choose the right communication method for your automation project.

09/08/2026

This wiring diagram details the power and control circuit layout for a 3-phase electric crane hoist system, illustrating directional motor control and safety integration

Adresse

Quebec, QC

Heures d'ouverture

Lundi 9am - 5pm
Mardi 9am - 5pm
Mercredi 9am - 5pm
Jeudi 9am - 5pm
Vendredi 9am - 5pm

Téléphone

+15148409738

Notifications

Soyez le premier à savoir et laissez-nous vous envoyer un courriel lorsque 3JIndustry publie des nouvelles et des promotions. Votre adresse e-mail ne sera pas utilisée à d'autres fins, et vous pouvez vous désabonner à tout moment.

Contacter L'entreprise

Envoyer un message à 3JIndustry:

Raccourcis

Partager