Hurricane Tech Co., Ltd.

Website

Hurricane Tech Co., Ltd. Piezoelectric Ceramic Manufacturer in China

What does d15 tell you—and what does it not—when selecting a shear piezo actuator?Shear-mode PZT generates useful displa...
20/09/2026

What does d15 tell you—and what does it not—when selecting a shear piezo actuator?

Shear-mode PZT generates useful displacement parallel to its mounting interface. This means the coordinate system, load path, bonding, guiding, and protection from peel loads must be defined before comparing actuator options.

This guide explains how polarization, electric field, and output displacement relate in a common d15 description—and why a material coefficient cannot be converted directly into finished actuator travel.

Key points:
- Distinguish a single shear plate, shear stack, multi-axis assembly, and longitudinal stack.
- Define polarization, electric-field direction, fixed and moving faces, and positive displacement on the drawing.
- Evaluate bond-line stiffness, alignment, cross-axis motion, guide compliance, and remote tool-point travel.
- For RFQs, specify load-point travel and force, voltage waveform, mounting method, allowable errors, environment, and acceptance tests.

For engineers and technical buyers, the guide provides a practical framework for evaluating shear-mode PZT in scanning, positioning, and vibration-control designs.

Read the full guide here

https://chinaultrasound.com/en/blog/shear-piezo-actuators/

Learn how polarization, electric field and lateral displacement define d15 shear-mode PZT, how shear stacks differ from longitudinal stacks, and when to use them.

A stable thickness reading is not necessarily a correct one. Corrosion monitoring and precision thin-wall measurement us...
18/09/2026

A stable thickness reading is not necessarily a correct one. Corrosion monitoring and precision thin-wall measurement use ultrasonic time-of-flight, but they require different probe structures, instrument settings, calibration methods, and scanning procedures.

This guide explains how engineers and technical buyers can evaluate the complete probe–instrument combination instead of selecting by frequency alone:

- Corrosion and remaining-wall measurements often involve rough surfaces, pitting, coatings, curves, and local minimum-thickness capture, where twin-crystal probes and V-path correction matter.
- Thin-wall measurement requires the system to separate closely spaced interface and back-wall echoes through suitable pulse duration, bandwidth, timing mode, and probe structure.
- Validation should include representative materials, known thin and thick references, A-scan or waveform checks, temperature, curvature, coating, coupling, and approved instrument settings.

The guide also outlines the key information to provide when specifying or sourcing a thickness probe.

Read the full guide here

https://deep-minds.com/en/blog/ultrasonic-thickness-probe-selection/

Choose an ultrasonic thickness probe by separating corrosion and remaining-wall surveys from precision thin-wall measurement, then checking echoes, surface, range and instrument compatibility.

How do you select a piezo stack actuator without treating free stroke and blocked force as simultaneously available?A me...
17/09/2026

How do you select a piezo stack actuator without treating free stroke and blocked force as simultaneously available?

A mechanism normally operates between these two boundary conditions. The practical working point depends on the required displacement, force, load stiffness, interfaces and operating conditions—not on the largest catalog number.

This guide explains how engineers and technical buyers can evaluate:

- Working displacement and force using the actuator–load stiffness relationship
- Stack length, cross-section, shape and mechanism compliance
- Controlled compressive preload, alignment and interface conditions
- Capacitance, waveform, voltage slew rate and peak driver current

It also covers RFQ requirements, sensor placement, verification under real load, and common failure modes such as side loading, preload loss and undersized drivers.

Read the full guide here

https://chinaultrasound.com/en/blog/piezo-stack-actuator-selection/

Select a piezo stack by working force and stroke, stiffness, size, capacitance, drive conditions and preload instead of comparing free stroke or blocked force alone.

Does a 100 kHz PZT tube automatically produce a 100 kHz underwater transducer? Not necessarily. Water loading, potting, ...
16/09/2026

Does a 100 kHz PZT tube automatically produce a 100 kHz underwater transducer? Not necessarily. Water loading, potting, housing and boundary conditions can shift the completed assembly’s resonance, impedance and bandwidth.

This guide explains how to evaluate a radially polarized PZT ceramic tube as part of a transmit, receive or transceive system—not as a standalone guarantee of acoustic performance.

Key selection points:
- Radial mode depends on electrode location, polarization and dimensions, not tube shape alone.
- OD, ID, wall thickness and length affect stiffness, capacitance, active area, package constraints and unwanted mode coupling.
- Transmit designs emphasize drive field, loss, heat and stress; receive designs require attention to sensitivity, noise, capacitance and electronics loading.
- RFQs should define electrode layout, geometry, operating liquid, pressure environment and air/immersed acceptance methods.

For engineers and technical buyers, the article also outlines a three-state verification plan from free ceramic to immersed assembly.

Read the full guide here

https://chinaultrasound.com/en/blog/pzt-tubes-underwater-sonar/

Learn how radial mode, tube geometry, water loading, electrodes and housing affect PZT tube selection for underwater sonar transmitters and receivers.

A probe that produces a clean echo on flat steel can still be unsuitable for a weld, rough casting, or automated immersi...
15/09/2026

A probe that produces a clean echo on flat steel can still be unsuitable for a weld, rough casting, or automated immersion line. The practical starting point is the inspection path: defect orientation, accessible surfaces, beam direction, frequency, aperture, and packaging.

This guide helps engineers and technical buyers compare probe categories while keeping procedure validation in view:

- Straight-beam contact probes suit approximately normal sound paths, such as plate or forging volume checks, when one flat surface is accessible.
- Angle-beam probes introduce refracted sound to inspect weld volume and planar discontinuities; angle and sound path must match thickness, geometry, scan surface, and target orientation.
- Immersion probes use a controlled water path for repeatable positioning and automated scanning, with attention to stand-off, focus, bubbles, alignment, and motion control.
- Frequency and aperture affect pe*******on, resolution, beam spread, and coverage. Candidate probes should be verified with the same instrument and representative reference reflectors.

Read the full guide here

https://deep-minds.com/en/blog/ultrasonic-ndt-probe-selection/

Compare straight-beam, angle-beam and immersion ultrasonic NDT probes by inspection geometry, material, frequency, beam path and manual or automated use.

How should an OEM specify a piezo ring for a vibrating-mesh atomizer without confusing free ceramic data with assembled ...
11/09/2026

How should an OEM specify a piezo ring for a vibrating-mesh atomizer without confusing free ceramic data with assembled performance?

A mesh atomizer is a coupled system: the PZT ring, adhesive, metal membrane, housing, electrode connection and liquid all influence the response. OD, ID and thickness affect active area, stiffness, capacitance, bond area and the mesh’s deformation zone—not resonance alone.

Key points for engineering selection:

- Separate incoming inspection of dimensions, flatness, capacitance and free-state impedance from wet assembled testing.
- Treat adhesive thickness, modulus, coverage, cure and alignment as mechanical design variables.
- Distinguish free-ring, bonded, housed and wet operating measurements; each state may require its own acceptance window.
- Define drive waveform, duty cycle, liquid condition and measurements for current, output, temperature and drift.

The guide also outlines handling controls for ultra-thin rings and the technical details an OEM should include in an RFQ.

Read the full guide here

https://chinaultrasound.com/en/blog/piezo-rings-mesh-atomizers/

Understand how piezo ring diameter, thickness, bonding and assembled resonance affect a mesh atomizer, and which component and test details an OEM should specify.

Is a same-size, same-frequency ultrasonic transducer really a replacement? Not necessarily. Compatibility depends on how...
10/09/2026

Is a same-size, same-frequency ultrasonic transducer really a replacement? Not necessarily. Compatibility depends on how the candidate performs in the original system—not only on its label or dimensions.

This guide helps engineers and sourcing teams define the replacement scope and compare component-level and system-level evidence before approving a change.

- Decide whether the project requires an exact drop-in, form-fit-function, or functionally equivalent redesign.
- Compare frequency, bandwidth, impedance, capacitance, waveform, ringing, beam, sensitivity, and cable loading.
- Check mechanical interfaces, mounting, sealing, cable and connector details, and environmental conditions.
- Validate candidates on the original circuit and fixture with representative media, targets, settings, and calibration requirements.

The article also outlines what to document in an RFQ and how to structure side-by-side testing using original samples and defined acceptance criteria.

Read the full guide here

https://deep-minds.com/en/blog/ultrasonic-transducer-replacement/

Evaluate ultrasonic transducer replacement by original application, frequency, impedance, capacitance, waveform, beam, mechanics, environment, calibration and system validation.

A PZT ring labeled “20 kHz” is not a complete selection specification. In a bolt-clamped ultrasonic plastic welding conv...
09/09/2026

A PZT ring labeled “20 kHz” is not a complete selection specification. In a bolt-clamped ultrasonic plastic welding converter, the operating resonance belongs to the full acoustic stack—including the ceramic rings, electrodes, metal masses, center bolt, preload, booster, horn and mechanical load.

This guide explains how to evaluate replacement or customized PZT rings based on assembled converter behavior rather than nominal frequency alone.

- How ring OD, ID, thickness and quantity affect stiffness, capacitance, electric field and stack tuning
- Why Qm, dielectric loss, coupling, drive field and temperature stability must be considered together
- What to specify for polarization, electrode layout, bolt clearance, contact faces and preload
- How to use original dimensions, impedance sweeps and controlled drive testing during replacement validation

A practical reference for engineers, product developers and technical buyers working with ultrasonic welding converters.

Read the full guide here

https://chinaultrasound.com/en/blog/pzt-rings-ultrasonic-plastic-welding/

Learn how PZT ring material, Qm, dimensions, stack layout and bolt preload interact in ultrasonic plastic welding transducers, and what to specify before replacement or customization.

Can an ultrasonic transducer designed for air simply be submerged? Not necessarily. Changing the propagation medium chan...
08/09/2026

Can an ultrasonic transducer designed for air simply be submerged? Not necessarily. Changing the propagation medium changes acoustic loading, impedance, resonance, attenuation, beam behavior, sealing requirements, and electrical matching.

This guide helps engineers and technical buyers compare air-coupled, liquid-coupled, wall-coupled, and immersion designs before selecting frequency or housing.

• Air-coupled transducers must address the large impedance mismatch between piezoelectric ceramics and air, while liquid coupling introduces stronger acoustic loading.
• Frequency selection depends on sound speed, attenuation, wavelength, range, resolution, aperture, and the actual medium.
• Housing, protective faces, adhesives, seals, pressure, corrosion, bubbles, and temperature can all affect performance.
• RFQ and validation should define the complete acoustic path, interfaces, operating conditions, electronics, and prototype tests.

The article also outlines a practical workflow for interface definition, loaded impedance evaluation, beam assessment, and environmental validation.

Read the full guide here

https://deep-minds.com/pt/blog/air-vs-liquid-coupled-ultrasonic-transducers/

Compare transdutores ultrassônicos acoplados ao ar e ao líquido quanto à impedância acústica, acoplamento, atenuação, frequência, carcaça, vedação, pressão, feixe e aplicação.

What does “coated PZT ceramic” actually mean on an engineering drawing or RFQ? The term may refer to an electrode, a pla...
07/09/2026

What does “coated PZT ceramic” actually mean on an engineering drawing or RFQ? The term may refer to an electrode, a plated finish, a protective coating, an insulating layer, or full encapsulation—and each serves a different function.

This guide helps engineers and technical buyers define the required surface structure based on electrical connection, environmental exposure, insulation, bonding, and assembly integration.

• Distinguish electrode metallization from plating and finishes used for soldering, conductive adhesive, wire bonding, or pressure contact.
• Specify coverage, underlayer, connection areas, polarity, thickness where critical, and the verification method.
• Separate protective coatings, insulation, conformal coverage, and encapsulation by their boundaries and intended risks.
• Consider how added layers, solder joints, wires, or encapsulation may affect capacitance, resonance, damping, acoustic interfaces, and mechanical loading.

A clearer specification can reduce ambiguity when requesting custom PZT surface treatments.

Read the full guide here

https://chinaultrasound.com/en/blog/pzt-ceramic-coatings-surface-finishes/

Understand the differences among PZT electrodes, plated finishes, protective coatings, insulation and encapsulation, and learn what to specify on a drawing or RFQ.

Address

1603A, Building A, Jieshun Technology Center, Longhua District
Shenzhen
518000

Opening Hours

Monday 09:00 - 18:00
Tuesday 09:00 - 18:00
Wednesday 09:00 - 18:00
Thursday 09:00 - 18:00
Friday 09:00 - 18:00

Alerts

Be the first to know and let us send you an email when Hurricane Tech Co., Ltd. posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Shortcuts

Share