Correct wiring of a UK mains plug.Left image: Earthed – usually class 1, high power 13A equipment.Right image: Class 2 d...
30/05/2024

Correct wiring of a UK mains plug.
Left image: Earthed – usually class 1, high power 13A equipment.
Right image: Class 2 double insulated equipment requiring no earth, low power 3A.
Note: Equipment class and power / fuse rating are not related.
Top central pin, Green & Yellow wire = Earth / ground.
Lower left pin, Blue wire = Neutral.
Lower right pin, Brown wire = Live.
Points to watch out for: Wires are connected in the correct order, No copper cores visible, No sharp kinks or trapped conductors, No loose screws (very common), Cord grip in place and gripping the outer flex NOT cores, No cores viable when plug closed, correct fuse for the equipment fitted, no paper instructions on the plug face [not shown].

The teams’ main geographical area of operation.
21/05/2024

The teams’ main geographical area of operation.

Damaged socket found in kick plate cable system under a desk.Possibly damaged by vacuum cleaner or shoes / boots. Danger...
19/05/2024

Damaged socket found in kick plate cable system under a desk.
Possibly damaged by vacuum cleaner or shoes / boots.
Danger of injury from contact with live parts is obvious. Also fire risks if water or insects or small animals enter the socket and connected system.
Easily repaired relatively cheaply by a qualified person.
Damaged probably would not have been found without a regular inspection as it’s easily hidden by bags, shopping, office supplies or work samples.

Why anti tamper doesn't work. Checking a plug needs to included an internal visual inspection. This was caused by a loos...
29/04/2024

Why anti tamper doesn't work. Checking a plug needs to included an internal visual inspection. This was caused by a loose connection. Incorrect wiring and fuses are also common.

A little about PAT testing and us for when you need it.
29/04/2024

A little about PAT testing and us for when you need it.

Address

Daventry
NN114SP

Telephone

+447808480048

Website

Alerts

Be the first to know and let us send you an email when Mechanical Electrical PAT South Central posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Mechanical Electrical PAT South Central:

Share