MVHR by Forbes Solutions

MVHR by Forbes Solutions We design, install and commission Mechnical Ventilation with Heat Recovery systems

Recently we have been installing some centralised fan units in a property that required an upgrade to their house ventil...
15/07/2026

Recently we have been installing some centralised fan units in a property that required an upgrade to their house ventilation for architects Mwclubb in Huntly.

These run continuously extracting from your kitchens, bathrooms and utility spaces brining in fresh air through your trickle vents.

These replace your standard fans and kitchen extractor, run quietly in the background and increase ventilation when there is increased humidity.

Does your property suffer from poor ventilation? We can help

If you are installing an MVHR system on your project and looking for the best quality equipment please get in touch, we ...
12/07/2026

If you are installing an MVHR system on your project and looking for the best quality equipment please get in touch, we can help.

While replacing the unit at this project we also routed the Intake duct to the cooler, shaded gable of the house. This i...
07/07/2026

While replacing the unit at this project we also routed the Intake duct to the cooler, shaded gable of the house.

This is a stainless vent cover that allows free flow of air. They are available in a variety of sizes to suit the duct for the MVHR unit

When we moved the Zehnder Q450 we saw this water staining on the chipboard below!!The installer had not installed the tw...
04/07/2026

When we moved the Zehnder Q450 we saw this water staining on the chipboard below!!

The installer had not installed the two blanking plugs on the underside of the unit.

The machine was specked with enthalpy so no requirement for a condensate drain but it did need the blanks to seal the unit!

This is the second project in the last month we have been working at where the condensate has not been installed correctly..

Replacing a Zehnder Q450 with a Q600 to resolve a bad original installation where the ductwork was causing pressure issu...
03/07/2026

Replacing a Zehnder Q450 with a Q600 to resolve a bad original installation where the ductwork was causing pressure issues when achieving airflow. Ideally replace the ductwork but wasn’t an option so the larger capacity machine was the solution. First was to get the units up and down with millimetres of space.

We always have solutions

So if you have had the MVHR system installed you need to get it commissioned - we can help.We would give the system a ch...
02/07/2026

So if you have had the MVHR system installed you need to get it commissioned - we can help.

We would give the system a check over visually for any issues with the install then set up the system by balancing the air supply and extract to the design ensuring the system is providing the ventilation that it should be.

Get in touch if we can help

Don’t forget your filter changes everyone.These are from a standard 180 days in a Zehnder q350 unit with the darker filt...
10/05/2026

Don’t forget your filter changes everyone.These are from a standard 180 days in a Zehnder q350 unit with the darker filter from the outdoor air entering the unit as expected.

This unit is in Aberdeen city, yours may differ depending on what surrounds your house.

We were commissioning a system installed by the home owner yesterday. We carried out a system test for max air flow befo...
05/05/2026

We were commissioning a system installed by the home owner yesterday. We carried out a system test for max air flow before we started our air flow balancing. 145m3 was the result - what? The unit can achieve 600m3 so what’s wrong?

We take a look and something is in the extract vent at the apex of the gable. Some scaffolding and a ladder revealed the issue.

A bag from the packaging had dropped into the unit unnoticed. When the machine was turned on it blew it up to the grill and left only a small amount open for the air to pass.

Bag removed and the unit was running like a dream.

We were asked for some help with the MVHR systems in this property. There were a number of issues but this one is import...
25/02/2026

We were asked for some help with the MVHR systems in this property. There were a number of issues but this one is important. The unit was installed in a cold loft but also it was installed behind this vertical post. No way to open up this unit for maintenance without completely disconnecting the ducts and a lot of effort - a very bad choice of location by the installer! More to follow

A large number of our installs are retrofits where we have to create spaces for the MVHR as the luxury of a plant room w...
24/02/2026

A large number of our installs are retrofits where we have to create spaces for the MVHR as the luxury of a plant room wasn’t designed into homes then. This is a cupboard we created in the hallway from a wardrobe in a bedroom. The walls were filled with acoustic insulation but the Zehnder machines are very quiet while in operation.
Not much extra room but so long as the access in front is clear allowing for servicing in the future that’s all you need!