💧 PSF Backwash Calculation – Kitna Water Chahiye?

Pressure Sand Filter ka effective backwash flow aur water requirement kaise calculate karein?

📌 Learn:
✅ Backwash Working Principle
✅ Filter Area Calculation
✅ Backwash Flow Rate
✅ Backwash Water Requirement

Real Engineering. Practical Knowledge!

Follow LIECL for more Water Treatment Engineering.

WTP | STP | ETP | RO | ZLD

STP WaterEngineering LIECL

11/11/2026

💧 Lamella Clarifier – Small Space, Maximum Settling!

Kya aap jaante hain inclined plates settling area ko kaise increase karti hain? 🤔

Is reel mein samjhiye:
✅ Working Principle
✅ Plate Spacing
✅ Surface Loading Rate
✅ Settling Efficiency

Learn practical Water Treatment Engineering with LIECL!

📌 Follow LIECL for more technical engineering knowledge.

WTP EnvironmentalEngineering WaterEngineering LIECL

10/11/2026

🚨 STP Mein RAS Flow Kitna Rakhna Chahiye?

Guesswork nahi, calculation se samjhiye! 💧

📌 Influent Flow = 100 m³/hr
📌 MLSS = 3,000 mg/L
📌 RAS Concentration = 9,000 mg/L
📌 Calculated RAS Flow = 50 m³/hr

⚙️ Remember: Actual RAS setting depends on sludge settling and clarifier performance.

Follow LIECL for practical water engineering calculations!

LIECL EngineeringReels

09/11/2026

🚨 Activated Carbon Filter Kab Fail Hota Hai?

WTP mein ACF ki performance kharab hone ke 4 common reasons! 💧

1️⃣ Carbon Media Exhaustion
2️⃣ Channeling
3️⃣ Improper Backwashing
4️⃣ High Suspended Solids Loading

⚙️ Practical Engineering Tip:
Backwashing aur carbon replacement dono alag processes hain!

Follow LIECL for practical WTP, STP, ETP, RO & ZLD engineering knowledge.

GAC IndustrialWaterTreatment LIECL

🪔 शुभ दीपावली! Happy Diwali! ✨May the festival of lights illuminate your life with happiness, prosperity and new opportu...
08/11/2026

🪔 शुभ दीपावली! Happy Diwali! ✨

May the festival of lights illuminate your life with happiness, prosperity and new opportunities.

At Lal Ion Exchange and Chemicals Pvt. Ltd. (LIECL), we believe in building brighter futures through innovation, trust and sustainable solutions.

Wishing our valued clients, partners, employees and their families a Diwali filled with joy, success and prosperity.

Let's continue building a brighter and more sustainable tomorrow together!

Happy Diwali from Team LIECL! 🪔

Sustainability Innovation TeamLIECL FestivalOfLights

🪔✨ Diwali is brighter when we celebrate together!At LIECL, we believe that our people are our greatest strength. This Di...
07/11/2026

🪔✨ Diwali is brighter when we celebrate together!

At LIECL, we believe that our people are our greatest strength. This Diwali, we celebrated the festival of lights by sharing gifts, smiles and moments of gratitude with our amazing team.

Every milestone we achieve is a result of the dedication, hard work and commitment of our employees.

Here's to togetherness, teamwork and brighter beginnings!

Wishing everyone a very Happy Diwali from Team LIECL! 🪔

LIECL

07/11/2026

NaOH Dosing Calculation in Water Treatment | Practical Engineering Example

How much Caustic Soda (NaOH) is required to increase pH in an industrial WTP / ETP?

NaOH (Sodium Hydroxide) is commonly used in water and wastewater treatment for pH adjustment and neutralization.

Let’s understand its dosing calculation with a simple engineering example.

Given Data:

* Water Flow = 10,000 LPH
* Required NaOH Dose = 20 mg/L
* NaOH Solution Strength = 10% w/w

Step 1: Calculate Pure NaOH Requirement

Formula:

Pure Chemical Requirement (g/hr) =

(Flow × Dose) / 1000

Calculation:

= (10,000 × 20) / 1000

= 200 grams/hour

Step 2: Calculate 10% NaOH Solution Requirement

Solution Requirement = Pure NaOH Requirement / Solution Strength

= 200 / 0.10

= 2,000 grams/hour

= 2 kg/hour of 10% NaOH solution

Final Engineering Result:

* Pure NaOH Required = 200 g/hr
* 10% NaOH Solution Required = 2 kg/hr

Important Engineering Considerations

1. Actual NaOH demand depends on raw water alkalinity, acidity and buffering capacity.
2. Determine the required dose through laboratory titration or jar testing.
3. Monitor pH continuously or at suitable operating intervals.
4. Consider solution density when converting kg/hr into LPH for dosing pump selection.
5. NaOH is highly corrosive. Follow appropriate PPE, chemical handling and supplier safety instructions.

Remember: Correct chemical dosing is not just about calculation; it is about maintaining stable process performance and safe plant operation.

At LIECL, we share practical engineering knowledge related to:

WTP | STP | ETP | RO | ZLD

Follow LIECL for more practical water treatment calculations and industrial engineering knowledge.

IndustrialWaterTreatment ProcessEngineering LIECL

06/11/2026

⚙️ Unit Operation vs Unit Process – Do You Know the Difference?

Every chemical and water treatment plant uses both Unit Operations and Unit Processes.

💧 Unit Operation = Physical Change

Filtration

Distillation

Evaporation

Heat Transfer

RO Separation

🧪 Unit Process = Chemical Reaction

Neutralization

Oxidation

Chlorination

Chemical Precipitation

📌 Remember: Physical transformation = Unit Operation
Chemical transformation = Unit Process

Understanding these concepts is essential for every Chemical, Process and Water Treatment Engineer!

Follow CPE Hub for practical engineering knowledge.

ChemicalProcess PlantEquipment EngineeringEducation CPEHub IndustrialEngineering

05/11/2026

🚨 RO PLANT PRODUCTION DOWN? DON'T BLAME THE MEMBRANE YET!

Are you noticing a sudden drop in your Reverse Osmosis (RO) plant's permeate production?

Before replacing the RO membrane, check one important performance indicator:

💧 NORMALIZED PERMEATE FLOW (NPF)

Unlike actual permeate flow, normalized permeate flow accounts for changes in operating conditions and helps evaluate membrane performance.

📊 Practical Engineering Example

Consider an RO plant:

Baseline Normalized Permeate Flow = 10 m³/hr

Current Normalized Permeate Flow = 7 m³/hr

Performance Ratio:

(7 ÷ 10) × 100 = 70%

This indicates a 30% decline from baseline performance.

⚙️ Why Does Normalized Permeate Flow Decrease?

Possible reasons include:

1️⃣ Membrane scaling
2️⃣ Organic and colloidal fouling
3️⃣ Poor pretreatment performance
4️⃣ Changes in feed pressure and temperature
5️⃣ Improper RO operating conditions

🔍 What Should Engineers Monitor?

✅ Feed pressure and temperature
✅ Feed water TDS
✅ Differential pressure across membrane stages
✅ Permeate flow and quality
✅ Membrane cleaning requirements

Important: Always use the membrane manufacturer's normalization procedure and correction factors for accurate performance evaluation. A decline in normalized flow is a warning signal, not proof of membrane failure.

💡 Smart engineers don't just monitor production. They monitor membrane performance!

At LIECL, we focus on practical and efficient Water & Wastewater Treatment Solutions.

📞 Contact: +91 7974219764
🌐 Website: https://liecl.com

Follow LIECL for practical water engineering knowledge and industrial water treatment insights.

IndustrialWaterTreatment WastewaterTreatment LIECL

04/11/2026

💧 DM Plant Anion Tank – Deep Dive!
Anion Tank water se Chloride, Sulphate, Silica jaise unwanted ions kaise remove karta hai? ⚙️
Samjhiye Ion Exchange Process aur NaOH Regeneration ka complete concept, sabse aasaan language mein!
📌 Follow LIECL for practical Water Treatment Engineering.
WTP | STP | ETP | RO | DM | ZLD

Address

10A/Sector I , Govindpura Industrial Area
Jahangirabad
462023

Alerts

Be the first to know and let us send you an email when LIECL posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to LIECL:

Shortcuts

Share

Nearby engineering companies