Goppa Refrigeration and Air Conditioning Contractors - POM Branch

Goppa Refrigeration and Air Conditioning Contractors - POM Branch We Sweat To Beat The HEAT
In Goppa, We Cool

πŸ“ On-Site at Pacific Adventist University (PAU)Is your AC struggling with the heat? We just gave this 18,000 BTU unit at...
12/02/2026

πŸ“ On-Site at Pacific Adventist University (PAU)

Is your AC struggling with the heat? We just gave this 18,000 BTU unit at Pacific Adventist University the ultimate refresh! 🧊⚑

Our team recently completed a Comprehensive Chemical Strip Service on an 18,000 BTU High-Wall Split unit. To ensure the unit returned to its peak manufacturer standards, we performed a deep technical clean of:

A standard wipe-down isn't enough. Our Full Chemical Service goes deep:

βœ… Indoor Unit: Blower wheel, evaporator coils, and air filters. Stripped and washed.
βœ… Outdoor Unit: High-pressure chemical wash of the condenser. Cleared of all debris
βœ… System Health: Flushed drainage lines to prevent leaks and conducted full electrical component safety checks.

The result? Maximum airflow and "like-new" cooling performance. ❄️ Keep your learning environment cool and comfortable!

We don’t just cleanβ€”we restore! This unit is now back to its standard for perfect, ice-cold cooling. πŸ’¨

Need a service? Message us today! πŸ“₯

Completed a full chemical service on the AC systems at Port Moresby General Hospital today. Ensuring clean, cool air for...
19/01/2026

Completed a full chemical service on the AC systems at Port Moresby General Hospital today. Ensuring clean, cool air for our city's primary healthcare facility is always a priority! πŸ₯❄️

Appliance: Panasonic Air Conditioning UnitCapacity: 18,000 BTURefrigerant Type: R410aInitial Reported Fault:The air cond...
17/08/2025

Appliance: Panasonic Air Conditioning Unit
Capacity: 18,000 BTU
Refrigerant Type: R410a

Initial Reported Fault:
The air conditioning unit was non-operational and unable to start.

Diagnosis:
Initial inspection revealed a failed compressor. A secondary fault with the run capacitor was identified during the post-installation startup test.

Corrective Actions Performed:

Compressor Replacement: The faulty 18,000 BTU compressor was removed from the system. The connecting pipes were cut with a grinder for efficient removal.

Installation: A new compressor was installed, and the refrigerant lines were connected by brazing with MAPP gas.

System Preparation: A deep vacuum was pulled on the system to remove all moisture and non-condensable gases.

Leak Test: The system was pressurized with R410a refrigerant to verify the integrity of the brazed joints. No leaks were detected.

Capacitor Replacement: Upon initial power-up, the new compressor was humming but failed to start. The run capacitor was diagnosed as faulty and replaced with a new 55Β΅F capacitor.

Final Test: The system was powered on again. The compressor engaged immediately and operated smoothly.

Final Result:
The root causes of the failure (compressor and capacitor) have been resolved. The Panasonic 18,000 BTU air conditioner is now fully functional and operating correctly.

Goppa Refrigeration and Air Conditioning Contractors - POM Branch

γ‚šviralγ‚·fypγ‚·γ‚š

Fridges can experience problems with the control board, leaks, or the compressor, but maintaining a stable power supply ...
22/07/2025

Fridges can experience problems with the control board, leaks, or the compressor, but maintaining a stable power supply is crucial to prevent further issues. Blackouts can cause damage, so using power surge protectors is recommended.

Here's a more detailed breakdown:

Common Fridge Problems:

1.Control Board:
The electronic control board manages various fridge functions. Problems here can lead to cooling issues, temperature fluctuations, or even the fridge not turning on.

2.Leaks:
Leaks can stem from a clogged defrost drain, a damaged door seal, or condensation issues.

3. Compressor:
The compressor is the heart of the cooling system. A faulty compressor can result in the fridge not cooling, making unusual noises, or even tripping the circuit breaker.

The Impact of Blackouts:

1. Power surges:
When power is restored after an outage, it can come back with a surge, potentially damaging sensitive electronic components in the fridge, including the control board and compressor.

2.Mechanical issues:
Blackouts can also cause mechanical problems, like the compressor seizing or the fan motor failing, due to the sudden loss and restoration of power.

3.Ice buildup:
If a blackout occurs during the defrost cycle, it can lead to excessive ice buildup, which can further damage the fridge.

How to Protect Your Fridge:

1. Power surge protectors:
Using a power surge protector can help shield your fridge from voltage spikes when the power comes back on after an outage.

2. Regular maintenance:
Keeping your fridge clean, checking door seals, and ensuring proper ventilation can help prevent many common issues.

3. Professional help:
If you experience persistent problems or suspect a major issue, it's best to consult a qualified appliance technician.

22/07/2025

Celebrating my 1st year on Facebook. Thank you for your continuing support. I could never have made it without you. πŸ™πŸ€—πŸŽ‰

First floor full y painted πŸ–ŒπŸ–ŒπŸŽ¨
23/06/2025

First floor full y painted πŸ–ŒπŸ–ŒπŸŽ¨

Air Conditioning Full Strip Service πŸ‘ŒπŸ™ β€οΈπŸ’žβ€οΈ
04/06/2025

Air Conditioning Full Strip Service
πŸ‘ŒπŸ™

β€οΈπŸ’žβ€οΈ

Address

Gahunagaudi Drive, Gerehu Stage 1
Port Moresby
121

Opening Hours

Monday 08:00 - 17:00
Tuesday 08:00 - 17:00
Wednesday 08:00 - 17:00
Thursday 08:00 - 17:00
Friday 08:00 - 17:00
Saturday 08:00 - 12:00

Telephone

+67575755253

Website

Alerts

Be the first to know and let us send you an email when Goppa Refrigeration and Air Conditioning Contractors - POM Branch posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Goppa Refrigeration and Air Conditioning Contractors - POM Branch:

Share