Bevtron Bevtron offers expert electrical engineering services to residential, industrial & commercial businesses.

From preventive maintenance & thermal scanning to power quality analysis & signing, we ensure your systems run safely, efficiently & reliably.

BEVTRON Electrical conducts thorough Site Inspections & Design Audits to ensure every electrical system is safe, efficie...
29/05/2026

BEVTRON Electrical conducts thorough Site Inspections & Design Audits to ensure every electrical system is safe, efficient, and built according to standards.

*e *esignandseal

Another safe and reliable installation by BEVTRON Electrical Services!From panel mounting to organized breaker layout an...
27/05/2026

Another safe and reliable installation by BEVTRON Electrical Services!
From panel mounting to organized breaker layout and conduit works — we make sure every connection is built for safety, durability, and performance.

*E *esignandseal

Relay testing in action — verifying protection, ensuring reliable trip performance.
03/05/2026

Relay testing in action — verifying protection, ensuring reliable trip performance.

Small Facility — But Load Flow Still MattersVisited a small commercial facility with a common issue:Lights were flickeri...
23/03/2026

Small Facility — But Load Flow Still Matters

Visited a small commercial facility with a common issue:

Lights were flickering, motors slowing down, and breakers randomly tripping.

Running a load flow analysis in ETAP, we found the real problem:
Undervoltage at the far end of the system

Cause:
• Long cable runs
• Undersized conductors
• Load imbalance

Even in small facilities, poor load distribution can lead to:

• Equipment inefficiency
• Overheating of cables
• Higher power losses
• Shortened equipment life

Solution implemented:
• Adjusted load distribution
• Recommended proper cable sizing
• Balanced phase loading

The generator kept tripping but there was no fault.A facility complained that their generator breaker kept tripping ever...
17/03/2026

The generator kept tripping but there was no fault.

A facility complained that their generator breaker kept tripping every time the power transferred to backup. The first assumption was equipment failure.
But after modeling the system in ETAP, the real cause appeared. There was no fault.
The breaker’s instantaneous setting was too low, so the normal motor and transformer inrush during transfer was enough to trip the generator breaker.
A simple adjustment to the protection settings solved the issue.
No equipment replacement.
No generator repair.
Just proper power system analysis.

⚡ Is Your Electrical System Really Safe? ⚡Many buildings install breakers and panels without checking the *actual fault ...
13/03/2026

⚡ Is Your Electrical System Really Safe? ⚡

Many buildings install breakers and panels without checking the *actual fault current* of the system.

When a major fault happens, underrated breakers can fail or cause a total power shutdown.
With a professional Power System Study using ETAP, we can verify:
✔ Short Circuit Fault Levels
✔ Breaker Interrupting Capacity
✔ Protection Coordination (prevent whole-building blackout)
✔ Arc Flash Hazard for worker safety

Big Advantages:
• Prevent equipment damage
• Improve system reliability
• Increase electrical safety
• Ensure compliance with engineering standards

If your facility has 1600A–4000A main panels, generators, or solar systems, a power system analysis is highly recommended.

This 2500A Breaker Would Have Exploded During a FaultRecently reviewed a commercial building distribution system.Main pa...
11/03/2026

This 2500A Breaker Would Have Exploded During a Fault

Recently reviewed a commercial building distribution system.
Main panel rating: 2500A
Installed breaker interrupting capacity: 25kA

After running a short circuit analysis, the available fault current at the MSB was: 41.8 kA
That means during a major fault, the breaker could fail catastrophically.
Why did this happen?

Because the breaker rating was selected based on typical values, not actual system calculations.

Factors that increased the fault level:
• Utility fault contribution
• Low transformer impedance
• Short cable distance from transformer to MSB
After modeling the system using ETAP, the recommendation was to upgrade the main breaker to 50kAIC.

Lesson learned:
Never assume fault levels. Always calculate them.

Delivered Panel Interface
26/07/2025

Delivered Panel Interface

Delivered ABB Drives.
17/07/2025

Delivered ABB Drives.

ABB External Handle Delivered
02/07/2025

ABB External Handle Delivered

🔥 Catch electrical problems before they explode – without shutting down operations! 🔥Why wait for a costly breakdown whe...
30/04/2025

🔥 Catch electrical problems before they explode – without shutting down operations! 🔥

Why wait for a costly breakdown when you can detect 🫣hidden electrical hazards while your business runs normally? 𝐓𝐇𝐄𝐑𝐌𝐀𝐋 𝐒𝐂𝐀𝐍𝐍𝐈𝐍𝐆 is the smart, non-disruptive way to:

✅ Spot overheating components before they cause fires or failures
✅ Inspect live systems safely – no shutdowns needed
✅ Prevent surprise downtime that costs thousands per hour
✅ Get instant reports with clear action steps

📩 Message us today to book. 𝐖𝐞 𝐬𝐜𝐚𝐧. 𝐘𝐨𝐮 𝐤𝐞𝐞𝐩 𝐰𝐨𝐫𝐤𝐢𝐧𝐠.

👉 Get in touch with us: https://bevtron.wixstudio.io/website, message us or email [email protected].

*E

Address

Lipa City
4217

Alerts

Be the first to know and let us send you an email when Bevtron posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Bevtron:

Share