keys formulas for Solar1. Performance Ratio (PR)Formula:PR = (Actual Energy Output / (Irradiance × Area × Module Efficie...
06/04/2025

keys formulas for Solar

1. Performance Ratio (PR)

Formula:
PR = (Actual Energy Output / (Irradiance × Area × Module Efficiency)) × 100

OR simplified:
PR = (Actual Output / Expected Output) × 100

2. Capacity Utilization Factor (CUF)

Formula:
CUF = (Actual Energy Output in kWh) / (Installed Capacity × 24 × Total Days) × 100

3. Specific Yield

Formula:
Specific Yield = Annual Energy Output (kWh) / Installed Capacity (kW)

4. Inverter Efficiency

Formula:
Inverter Efficiency = (AC Output / DC Input) × 100

5. Module Efficiency

Formula:
Module Efficiency = (Max Power Output / (Irradiance × Module Area)) × 100

6. System Efficiency (Overall)

Formula:
System Efficiency = (Total AC Energy Output / Total Solar Irradiation Input) × 100

7. System Losses (%)

Formula:
System Losses = 100% - PR

8. Plant Availability (%)

Formula:
Plant Availability = (Operational Hours / Total Possible Hours) × 100

9. Grid Availability (%)

Formula:
Grid Availability = (Grid Uptime Hours / Total Hours) × 100

10. Plant Downtime (%)

Formula:
Plant Downtime = (Downtime Hours / Total Operational Hours) × 100

Example:

2 inverters out of 50 are down for 2 hours:

Total inverter-hours = 50 × 2 = 100

Affected = 2 × 2 = 4

Downtime = (4 / 100) × 100 = 4%

11. Temperature Loss

Formula:
Temperature Loss = Temperature Coefficient × (Module Temperature - 25°C)

12. Irradiance Loss

Formula:
Irradiance Loss = (Standard Irradiance - Actual Irradiance) / Standard Irradiance × 100

13. Soiling Loss

Estimate Based On:
Soiling Loss = % Reduction in Output due to Dirt on Panels

14. Shading Loss

Estimate Based On:
Shading Loss = % Loss due to Nearby Obstructions

15. Mismatch Loss

Caused By:
Variations in module performance in a string.
Mismatch Loss = % Difference between Expected and Actual Output of Series Modules

16. Cable Loss (I²R Loss)

Formula:
Cable Loss = I² × R × Time

Where I = current, R = resistance

17. Transformer Losses

Consist of:

Core Loss (constant)

Copper Loss = I² × R

18. Degradation Loss

Formula:
Degradation Loss = Annual Degradation Rate × Number of Years

19. Availability Losses

Include:

Equipment Outages

Maintenance Time

Grid Disconnection

20. Energy Yield (kWh/kWp)

Formula:
Energy Yield = Total Energy Output (kWh) / Installed Capacity (kWp)

24/03/2025
23/03/2025

Solar Panels prices are going down.

16/08/2024

Solar panel ka aj ka rate kya hay?

What would be the reason?
27/07/2024

What would be the reason?

20/07/2024

Another low quality infrastructure

Address

Street No 6
Lahore

Website

Alerts

Be the first to know and let us send you an email when Solar Nama posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Share

Category