ELMG Digital Power

  • Home
  • ELMG Digital Power
Website Contact the business

ELMG Digital Power Digital Control of Power Electronics. We aim to design and build the best digital controlled power electronic systems.
And we’d like to help you by doing this.

By doing that we believe we will change the world.

How do you partition a system for the best solution to the requirements. Who does it and why and did you even notice it ...
02/01/2024

How do you partition a system for the best solution to the requirements. Who does it and why and did you even notice it happening?

Partitioning is critical to product development.   And even more critical is partitioning digital power development where the team’s skills required do not fit into the traditional hardware software split.  This post was originally published in 2010.  It is re-run here as part of the ELMG Redux...

https://info.elmgdigitalpower.com/personalization_tokencontact.firstname-elmg-digital-power-news-december-2023?ecid=&utm...
02/01/2024

https://info.elmgdigitalpower.com/personalization_tokencontact.firstname-elmg-digital-power-news-december-2023?ecid=&utm_campaign=E-mail%20Newsletter&utm_source=hs_email&utm_medium=email

The Q number system is a fixed point system where the available bits are divided amongst the integer bits (those to the left of the decimal point), fractional bits (those to the right of the decimal point) and a sign bit. You may ask “I know how integers are represented in binary but not fractions...

Sic AC System Facts - September News Letter
15/09/2023

Sic AC System Facts - September News Letter

With inverter grid synchronisation the key problem is that the grid frequency can vary.  In fact the frequency of AC systems around the world is different and is constantly changing.

ELMG News March 2023Energy storage everywhere and a grid power converter to connect itGrid synchronization for energy st...
12/05/2023

ELMG News March 2023

Energy storage everywhere and a grid power converter to connect it

Grid synchronization for energy storage power electronic converter

Battery Types

Power Ramp Rates

Reactive Power

Communication

Safety Disconnection

Energy storage power electronic converter FAQs

Energy storage everywhere and a grid power converter to connect it.
Energy storage is everywhere or is being talked about everywhere. Adding an energy storage power electronic converter to the distribution or customer network allows

Load leveling across the day
Integration of local renewable sources such as solar and wind
Deferment of transmission investment
Reduction in CO2 emissions because peaking plants do not need to be run
Lowering energy cost by price arbitrage on daily demand variation
Historically the electrical grid has had energy flow from the large remote generator station out through the transmission and distribution network to customer loads. And the voltage profile was set up with transformer turns-ratios for this.

Top of utility pole with three power lines against blue sky at sunset
The transmission and distribution grid has historically transmitted power from central generation to the load.

Energy storage is DC so there needs to be a reversible DC to AC power converter to interface between the battery and the grid. This is where power electronics provides the glue between the DC and the AC grid.

Here at ELMG Digital Power, we’ve been working on grid-connected power converters since 1997 in applications including

Harmonic shunt active filters
Static VAr compensators from 2kVAr to 500MVAr
Solar Inverters
Micro Inverters
Grid Interactive UPS Inverters
Battery Energy Storage Inverters
Aerial View of Amazon River in Belem do Para, Brazil
Saving energy with grid energy storage reduces carbon dioxide emissions

Grid connection challenges
Grid connection challenges with an energy storage power electronic converter include grid synchronization usually with a PLL or a DSOGI, Low voltage fault ride through, designing the LCL filter, and connecting converters in parallel.

Grid synchronization for energy storage power electronic converter
The grid frequency and phase can vary, especially if there are faults or disturbances in the network.

PLL or DSOGI
The Phase-Locked Loop (PLL) keeps the inverter voltage synchronized to the grid. This allows the inverter digital control system to have the real and reactive power flow as requested. It also makes sure that if the grid frequency isn’t exactly the expected 50Hz, 60Hz or 400Hz then the system will still operate correctly.

The Dual second-order generalized integrator is used to implement an alternate type of frequency lock. It is often considered that DSOGI does a better job in the transient ride through. However, a well-tuned PLL is as effective as Grid voltages are sinusoidal for the most part.

Multicolored abstract pattern of sine waves for decoration and background with motifs of repetition and fluidity
Low voltage fault ride through
It is inevitable that there will be a fault in the AC system. Either two phases will connect together or one phase will connect to the ground or alternatively there can be some combination of phase to phase fault and ground fault. This causes a voltage disturbance that the inverter must “ride through”. To ride through the PLL must stay synchronized and the inverter must control the current as required by the grid code. (We’ll cover that later). So the PLL/DSOGI must be designed to ride through the voltage disturbance.

LCL Filter design
LCL filters are used to minimize the cost of the grid coupling filter. The higher order filter has some poorly damped dynamics so synthetic damping is provided by control or via the addition of a small damping resistor. (Some grid codes now require this damping resistor).

LCL filter
LCL filters provide low loss low cost grid connection

Ensuring that the LCL is correctly designed so that it can be controlled with a suitably, low-cost controller means that LCL design is critical to a successful battery energy storage converter. The AC grid impedance range specified for the converter is really important.

Contact us for energy storage converters

Paralleling converters
It is a product manager’s dream to be able to put energy storage power electronic converters in parallel in any combination. If this is to be a possibility then all of the

LCL filter design
Controller choice
PLL design
Parallel connection
need to be managed for parallel connection from the very beginning of the development. It is best to limit the required parallel connection combinations to a minimum as each requires verification and validation testing.

Battery energy storage interfacing to the battery
The key issues in interfacing an inverter to battery energy storage are

The allowed ripple current and voltage for the battery and what this means for the grid side LCL filter and voltage imbalance.
The charge and discharge rates allowed for the batteries
How to manage and coordinate with the battery management system (BMS)
Battery Types
There are two principal types of batteries used in energy storage

Lithium Ion
Lead Acid
Contact us for energy storage converters

Lithium Ion
Lithium-Ion (Li-Ion) batteries work unsurprisingly, by the ionization of lithium. The energy density is high. The key safety issue with lithium-ion cells is the risk of fire from excess temperature. Li-Ion cell safety needs to be actively managed.

State of charge and state of health systems for Li-Ion systems are widely available.

Lead-Acid
Lead-acid batteries have lead and sulphuric acid. The energy density of lead-acid batteries is lower than Li-Ion.

State of charge and state of health systems for lead-acid batteries are less effective than those for Li-ion.

Grid codes
The AC grid is one of the most reliable machines in the world. Blackouts in most countries occur irregularly. This reliability is the result of long experience and conservatism by system operators.



Battery energy storage converters connected near the load end of the network are an unmanaged and uncontrollable (in grid operator terms non-dispatchable) energy source. To ensure the AC grid machine stays reliable there are rules for connecting power and energy generation to the AC grid network. Energy storage is a generation source so it is covered by the rules for generators. These rules are called the Grid Code. Each country’s grid code is different as each country has a different AC network.

Contact us for energy storage converters

Power Ramp Rates
The most common and most useful rule for generating is that the real and reactive power ramp rates must be limited. The power cannot go up or down too fast. What does too fast mean? Typically the ramp rate limit is zero to maximum power in tens of minutes.

Reactive Power
Adding power to the grid causes the voltage to rise. And the grid was designed to supply power to the load rather than get power from the load. So the battery energy storage real power output may well cause the voltage to rise. This can be counteracted with reactive power draw to keep the voltage down. This reactive power requirement means that the inverter may well need a higher current rating and so will cost more.

Communication
Some Grid Codes have the requirement that each inverter be connected to a system operator communication network where the network operator can control the real and reactive power dispatch or how the real and reactive power are controlled together. These communication network standards are well established in mature solar markets, such as Germany.

Safety Disconnection
The principal safety requirement for the grid code is to disconnect the energy storage system if the AC grid fails. This is to ensure that anyone working on the AC lines is safe from electric shock. This anti-islanding is a requirement for all grid codes.

Closeup businesswoman hands holding white card sign with oil price text message isolated on grey wall office background. Retro instagram style image
Grid energy storage allows the integration of renewable energy and the reduction in the use of fossil fuels

Energy storage power electronic converter FAQs
How do you implement anti-islanding?

The simplest way is with a frequency or phase angle perturbation. The best way is with a grid impedance change detection system.

Why do they keep changing grid codes?

The key reason is that adding more embedded generation and storage is threatening the reliability of the grid so they are changing the rules.

What is the best way to design an LCL filter for a grid-connected battery energy storage converter?

Well, this is a massive question. The best answer is to start with the low voltage fault ride-through (LVFRT) and the PLL and then work backward from there. A current control bandwidth target of 1kHz is useful.

Three-level or two-level inverter for an energy storage power electronic converter?

Get some help before you start if you are designing a three-level inverter. Common mode is easier to deal with for three-level. Modulation is less easy.

Can ELMG Digital Power Design us a Grid Connected Battery Energy Storage Converter for 1MW?

Yes. Any power from 1kw, 10kw, 20kw, 100kw 1MW, 10MW to 100MW.

Can you do MV or HV battery energy storage power electronic converter?

Yes, this is possible and we have worked on 11kV and 66kV MV UPS converters and their static transfer switches. Battery banks are best below 1500Vdc and so a multi-level multiple converter solution might be a good idea. Or alternatively, transformer coupling for the step up is also a useful and economically competitive approach.

Is thyristor, IGBT SiC Mosfet, or Si Mosfet the best switch choice?

Thyristors and IGBT are the most rugged so are more robust in grid-connected battery energy storage converters. SiC or Si Mosfets are also suitable choices.

Contact us for energy storage converters

APEC2023 PSMA Industry Session
07/02/2023

APEC2023 PSMA Industry Session

The PSMA - Power Sources Manufacturers Association Reliability Committee is sponsoring an Industry Session at APEC: Applied Power Electronics Conference on Wednesday March 22nd, at 8:30 a.m. in the Orange County Convention Center in Orlando, Florida. Featuring speakers from leading industry and research organizations, the session (IS12) will explore different approaches to address reliability objectives in industries including Automotive, Marine, Military, and manufacturing systems.

Read more at https://psma.com/conferences/APEC -7410

PSMA Reliability Committee Invitation
All APEC attendees are invited to participate in the PSMA Reliability Committee meeting scheduled for Tuesday March 21 from 8:00 to 10:00 a.m. in room Salon 14 at the Rosen Centre, Orlando, FL to plan the program for the coming year. Participants are also encouraged to participate in the other PSMA meetings being held throughout the week.

Address


Alerts

Be the first to know and let us send you an email when ELMG Digital Power posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to ELMG Digital Power:

Shortcuts

  • Want your business to be the top-listed engineering company?

Share