Er Amir Rather

Er Amir Rather Expertly skilled professional with excellent physical stamina that makes me a valuable addition to a company's team.

08/02/2026

08/02/2026

Types of Maintenance:
1. Preventive Maintenance (PM)
2. Predictive Maintenance (PdM)
3. Corrective Maintenance (CM)
4. Condition-Based Maintenance (CBM) 5. Reliability-Centered Maintenance (RCM)

Maintenance Activities:
1. Inspection and testing
2. Lubrication and oil changes
3. Filter replacement
4. Valve maintenance
5. Pump maintenance
6. Motor maintenance
7. Transformer maintenance
8. Electrical system maintenance
9. Control system maintenance
10. Cooling system maintenance

Power Plant Maintenance Schedules:
1. Daily checks
2. Weekly inspections
3. Monthly maintenance
4. Quarterly maintenance
5. Annual maintenance
6. Outage maintenance (every 2-5 years)
Power Plant Maintenance Tools:
1. Computerized Maintenance Management System (CMMS)
2. Enterprise Asset Management (EAM) software
3. Predictive maintenance software
4. Vibration analysis tools
5. Thermal imaging cameras
6. Ultrasonic testing equipment
7. Motor condition monitoring devices
Benefits of Power Plant Maintenance:
1. Increased reliability
2. Reduced downtime
3. Improved efficiency
4. Extended equipment lifespan
5. Enhanced safety
6. Reduced maintenance costs
7. Improved regulatory compliance
Challenges in Power Plant Maintenance:
1. Aging infrastructure
2. Limited budgets
3. Skilled labor shortages
4. Complex systems
5. Regulatory requirements
6. Environmental concerns
7. Cybersecurity threats

Best Practices:
1.Develop a maintenance strategy
2. Implement a CMMS/EAM system
3. Conduct regular inspections
4. Train personnel on maintenance procedures
5. Analyze maintenance data
6. Continuously improve maintenance processes
7. Ensure regulatory compliance Power Plant Maintenance Standards:
1. IEEE standards (e.g., [EEE 1156)
2. ANSI/ISA standards (e.g., ANSI/ISA 99)
3. API standards (e.g., API 510)
4. ASME standards (e.g, ASME PTC 46)
5. NERC standards (e.g., NERC 750)
Power Plant Maintenance Software:
1. SAP PM 2. Oracle Maintenance Cloud 3. IBM Maximo 4. Infor EAM 5. Schneider Electric EcoStruxure 6. GE Digital Predix 7. Siemens SIMATIC IT

08/02/2026

πŸ”§ HVAC Thumb Rules & Formulas :
Heat Load Calculation :
Formula: Q=Area (sq.ft)Γ—Heat Load Factor (BTU/hr per sq.ft)
Example: 500Γ—30=15,000 BTU/hr β†’ TR=1.25
CFM Calculation:
Formula: CFM=Sensible Heat (BTU/hr)1.08Γ—Ξ”T
Example: 12,0001.08Γ—20=556 CFM
AHU / FCU Sizing
Rule: 1 TR=400 CFM
Example: 2 TR=800 CFM
Duct Sizing :
Velocity Limits: Main ducts β†’ 1400–1800 FPM
Example: 8001000=0.8 sq.ftβ‰ˆ14"Γ—10"
Chilled Water Flow Rate :
Formula: GPM=BTU/hr500Γ—Ξ”T
Example: 24,000500Γ—10=4.8 GPM
Pipe Sizing :
1" pipe β†’ 8–12 GPM
2" pipe β†’ 30–40 GPM
Example: 35 GPM β†’ Use 2"
Chiller Sizing :
Formula: TR=BTU/hr12,000
Example: 60,00012,000=5 TR
Cooling Tower Sizing :
Rule: Heat Rejection = 1.25Γ—Load
Example: 10 TR β†’ Tower = 12.5 TR
Pump Head Calculation :
Formula: Power (kW)=QΓ—HΓ—9.81EfficiencyΓ—1000
Example: 5Γ—20Γ—9.810.75Γ—1000=1.31 kW
Fresh Air Requirement :
Office: 15–20 CFM/person
Example: 20 people β†’ 300 CFM
Electrical Load :
Rule: 1 TR=1.25 kW
Example: 10 TR β†’ 12.5 kW
Condenser Water Flow :
Rule: 3 GPM per TR
Example: 15 TR β†’ 45 GPM
Return Air Duct :
Rule: 2 sq.in. . per CFM :
Example: 600 CFM β†’ 1200 sq.in. . β‰ˆ 10" Γ— 12"
VRV / VRF Capacity
Rule: 1 HP = 0.8 TR
COP: 3.5–4.5
Chilled Water Pipe Velocity :
Chilled Water: 3–12 ft/s
Condenser Water: 6–9 ft/s/.

08/02/2026


# Electricalwork

What is the name of this equipment? Comment Your Answer..?
31/05/2025

What is the name of this equipment? Comment Your Answer..?

What is the name of this equipment? Comment Your Answer.?
31/05/2025

What is the name of this equipment? Comment Your Answer.?

29/05/2025

𝐌𝐚𝐒𝐧 𝐏𝐫𝐨𝐛π₯𝐞𝐦𝐬 𝐒𝐧 π‚πžπ’π₯𝐒𝐧𝐠 π…πšπ§
Common Problems and Solutions:
Noisy Fan:
Loose screws, unbalanced blades, or worn-out bearings can cause noise. Tighten screws, balance blades using a balancing kit, or lubricate bearings.
Slow Speed:
Dust buildup, a faulty capacitor, worn bearings, or loose connections can cause slow speeds. Clean the fan, replace the capacitor, lubricate bearings, or tighten connections.
Fan Won't Turn On:
Check the power supply, circuit breaker, switch, and remote control (if applicable). Ensure the fan is receiving power and that the switch is functioning correctly.
Wobbling Fan:
Uneven blade weight or loose blade holders can cause a wobbly fan. Balance the blades or tighten loose blade holders.
Fan Doesn't Circulate Air Properly:
Check blade direction, ensure the down rod is secure, and verify the reverse switch is in the correct position.
Fan is Too Low or High:
Ensure the fan is installed at the recommended height (7-9 feet from the floor) for optimal airflow and safety.
Troubleshooting Steps:
Check Power Supply: Ensure the fan is receiving power by checking the circuit breaker and switch.
Inspect Blades: Clean blades, check for damage, and ensure they are properly balanced.
Tighten Screws: Check all screws and tighten any that are loose.
Lubricate Bearings: If the fan is noisy, lubricate the bearings.
Check Capacitor: If the fan's speed is slow, check the capacitor.

Hello plumber this problem solutionπŸ˜‚(β‹‹β–‚β‹Œ)(β‹‹β–‚β‹Œ)(β‹‹β–‚β‹Œ)(β‹‹β–‚β‹Œ)
29/05/2025

Hello plumber this problem solutionπŸ˜‚
(β‹‹β–‚β‹Œ)(β‹‹β–‚β‹Œ)(β‹‹β–‚β‹Œ)(β‹‹β–‚β‹Œ)

Address

Dubai

Telephone

08491094165

Website

Alerts

Be the first to know and let us send you an email when Er Amir Rather posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Er Amir Rather:

Share