04/04/2026
I installed this ac 3 years ago. 3 years ago I pressure tested the lineset and new evaporator coil, all good. Pulled a great vacuum.
The next year, I got a call saying the ac wasn’t working. It was iced up, the duct work isn’t great, filter was dirty. Got it up and running again. Working great again. No big deal.
Got a call the next year at the end of the season, same story. Air flow still isn’t great, but the filters have been changed regularly. Checked the refrigerant charge again and it was low this time! Saw some oil residue on the compressor… uh oh.
Went back this year before the heat comes, took the refrigerant out and pressure tested the lineset and indoor coil, and condenser separately. Found a manufacturer leak at the compressor.
Manufacturer warranty for the compressor only, not the entire outdoor condenser and not labour. Checked out the compressor electrically and did a pump down test previous to taking out the charge. Compressor is fine.
Instead of waiting weeks for a compressor, I just fixed it. Took 5 minutes.
When the heat comes, I’ll go back and fine tune the refrigerant charge and it should be good now!
Sometimes new out of the box can have issues. I can fix that. 👍