First couple of clips is how the boiler was left after its was installed few years ago, their was about 6-7 problems with it, condense to small through the e wall and not lagged with the soak away to close to house, flue not sealed to the brickwork and old flue hole not bricked up, under sized gas pipe only 13mb at the boiler, 13amp fuse in plug, retaining clip missing for control panel, no magnetic filter, scale reducer or shock arrester and old programmer plus boiler wire left on connection block with 240v if the old fused spur was turned on ⚡️. We rectified all of this as shown in the rest of the reel and now made safe to use, all parts supplied by Ross branch for great product sorting the condense out and helping keep the boiler clean.