Engr Njoku Christian

Directions Website

Engr Njoku Christian Contact information, map and directions, contact form, opening hours, services, ratings, photos, videos and announcements from Engr Njoku Christian, Engineering service, Refinery Road, Port Harcourt.

30/10/2026

Rewinding of 87kw electric motor.

90kW ELECTRIC MOTOR: RESTORATION IN PROGRESS! Our 90kW electric motor is in the workshop, and the restoration work is un...
09/10/2026

90kW ELECTRIC MOTOR: RESTORATION IN PROGRESS!

Our 90kW electric motor is in the workshop, and the restoration work is underway!

First, we diagnose the fault, record the original winding data, and inspect the electrical and mechanical components.

Next, we carefully remove the old winding, inspect the stator core, clean the slots, and prepare for the new coils.

Then comes rewinding, connections, insulation, varnishing, reassembly and final testing.

Our goal? Restore reliable performance, minimise downtime, and keep your operations running efficiently!

IS A FAULTY MOTOR OR PUMP COSTING YOUR BUSINESS TIME AND MONEY?

Don't wait for a minor fault to become a major breakdown! Let our team help you get your equipment back in service with professional motor rewinding, repairs, servicing and maintenance.

Contact us today to discuss your equipment needs and arrange an inspection. Let's reduce downtime, protect your investment, and keep your machines working!

Your operations matter. We deliver engineering solutions that keep you moving!

⚡ 75kVA GENERATOR RESTORED! ANOTHER SUCCESSFUL REPAIR! At CELETEX ELECTRO-TECH CO. LTD, we turn generator problems into ...
09/10/2026

⚡ 75kVA GENERATOR RESTORED! ANOTHER SUCCESSFUL REPAIR!

At CELETEX ELECTRO-TECH CO. LTD, we turn generator problems into solutions!

FAULTS IDENTIFIED:
Burnt rotor and exciter windings.
Faulty rotating diodes.
Defective AVR producing over 300V at its lowest setting.

OUR SOLUTION:
Rewound the rotor and exciter windings.
Replaced the faulty diodes and AVR.

THE RESULT?
The generator is back in service, restored to factory settings!

Is your generator giving you trouble? Don't wait for a breakdown to cost you more!

Contact CELETEX ELECTRO-TECH CO. LTD for professional generator repairs, rewinding and maintenance.

We diagnose. We repair. We restore power! ⚡

Another regular day.
27/09/2026

Another regular day.

REWINDING of stator.
27/09/2026

REWINDING of stator.

27/09/2026

A 15 kW three-phase motor hums loudly when energized but refuses to start.The breaker doesn't trip.What would you check ...
27/09/2026

A 15 kW three-phase motor hums loudly when energized but refuses to start.
The breaker doesn't trip.

What would you check first?

What would be your diagnosis?

27/09/2026

Putting the Finishing touches on these jobs...

27/09/2026


Don't wait until a generator burns before checking what load you're putting on it.
Proper load management + functional protection + regular maintenance = less downtime and fewer expensive surprises.
At Celetex Electro-Tech, we don't just repair the fault we can see — we investigate what caused it.

26/09/2026

Following testing, dismantling and internal examination of the 75 kVA generator, significant damage was identified in the exciter and rotor windings, both of which showed evidence of severe thermal damage/burning.
The stator winding appears to remain in relatively good condition based on visual examination; however, electrical testing is required before it can be confirmed fit for continued operation.
Based on the condition of the damaged components and the evidence available during the inspection, overloading or prolonged operation under excessive electrical load is considered the most probable cause of the observed winding damage.
The generator should not be returned to service in its present condition. The damaged excitation and rotor components should be repaired or rewound, followed by comprehensive electrical and mechanical testing and a controlled load test before the generator is recommissioned.

Address

Refinery Road
Port Harcourt
500001

Alerts

Be the first to know and let us send you an email when Engr Njoku Christian posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Shortcuts

Share

Nearby engineering companies