HVAC Technologies USA, Inc.

HVAC Technologies USA, Inc. HVAC Technologies USA, Inc. is the prominent solutions provider of Engineered Air Conditioning and Ventilation Systems.

01/01/2016

Happy New Year to all Customers and Supporters of HVAC Technologies USA. We thank you for trusting us with your business in 2015 and look forward to a very successful 2016

09/14/2015

SYSTEMAIR: Topvex, TR800-208-3-CAV
Airflows up to 800 cfm
Integrated control system
Pre-programmed ERV controller
BMS compatible
Low sound level
Sensors
All sensors are factory installed and calibrated for ease of installation on-site. Each unit is tested and configured. The cost of installing controls at the factory is more economical as the unit is virtually plug n'play for any HVAC installer. Below are the sensor pre-installed with every unit:
- Outdoor, supply, return, & exhaust temperature
- Energy recovery wheel rotation status
- Dirty filter sensors
- Supply and exhaust fan airflow monitoring sensor
- Fan status
- Thermal overload sensor
- Hydronic coil frost protection

ERV Monitoring
There are three levels of alarm classes: A, B, C to handle high and low level priority conditions. Many alarms have adjustable set-points for your applications needs. Examples of alarm conditions are:
- Energy recovery wheel minimum efficiency
- Airflow set point
- High and low temperature set points (OA, RA, and SA)
- Sum alarm and external alarm input
- Plus many more . . .
Controller Capabilities
The highly configurable controller is geared toward ERV applications. It is pre-programmed from the factory and can accommodate changes to the program on-site via the remote display. Below are some available control features:

Supply air temperature control
Outdoor air temperature compensated supply air control
Room air temperature compensated supply air control

Cooling Towers by Coolwater Technologies - 111 Fifth Ave.
05/29/2015

Cooling Towers by Coolwater Technologies - 111 Fifth Ave.

HVAC Technologies USA adds Coolwater Technologies to our Commercial Line-up of products.  Cooling Towers are Manufacture...
02/24/2015

HVAC Technologies USA adds Coolwater Technologies to our Commercial Line-up of products. Cooling Towers are Manufactured locally in Long Island City New York. Units are CTI Certified and Factory Tested

HVAC Technologies USA wins Representative of the Month Award from Systemair for Innovative Design.
02/06/2015

HVAC Technologies USA wins Representative of the Month Award from Systemair for Innovative Design.

01/30/2015

Following is a list of formulas and equations required for proper evaluation and selection of HVAC Equipment!!
(C'mon, get Excited, LOL)

P = (GPM / Cv) squared
Pressure (in PSI), expressed as a function of flow and Cv (valve coefficient.

MAT = {(RAT x %RA) + (OAT x %OA)} / 100
Mixed Air Temperature, expressed as a function of return air temperature and percentage, and outside air temperature and percentage.

%OA = {(MAT – RAT) / (OAT – RAT)} x 100
Percentage of Outside Air, expressed as a function of mixed air, return air, and outside air temperatures.

BTUH = 1.08 x CFM x delta T
Airside Heat Transfer Equation

BTUH = 500 x GPM x delta T
Waterside Heat Transfer Equation

BTUH = KW x 3410
Conversion of kilowatts to BTUH

KW = BTUH / 3410
Conversion of BTUH to kilowatts

PSI = ft. hd. / 2.31
Conversion of “feet of head” to PSI

HVAC Technologies USA Receives Systemair North America Representative Award for   "ingenious re-circulation preheat that...
01/28/2015

HVAC Technologies USA Receives Systemair North America Representative Award for "ingenious re-circulation preheat that gave you the edge".

HVAC Technologies USA, Inc. provided design assistance and the Pool System for the Hyatt Place Hotel in Yonkers NY.  Poo...
01/28/2015

HVAC Technologies USA, Inc. provided design assistance and the Pool System for the Hyatt Place Hotel in Yonkers NY. Pool Systems require special consideration because of the corrosive chemicals in the pool environment

(2) 42,000 CFM Air Handlers Arrived in Modules in order to be rigged into the Rooftop Opening
01/28/2015

(2) 42,000 CFM Air Handlers Arrived in Modules in order to be rigged into the Rooftop Opening

Assisted the Engineer with Design and provided (2) 42,000 CFM Air Handlers for the Neuberger Museum Renovation Project.

11/03/2014

It's what you don't hear that's important!!

Systemaire/Changeaire manufactures the quietest "In Classroom" Air Handlers in the industry.

Sound data you can trust: Tested in accordance with AHRI 260 in
an accredited laboratory

The Systemair laboratory is designed and equipped to perform
testing in accordance with AMCA Standard 300, Reverberant
room method for sound and AMCA Standard 210 for
airflow performance.

Since the lab first earned AMCA accreditation, Systemair has
worked to continually increase the lab’s capabilities. This commitment to continued growth has allowed for testing units
in accordance with other standards and requirements, such
as AHRI 260 testing, safety regulatory agency testing like UL
and CSA, vibration testing, and full power analysis.

Sound and airflow test laboratory Our dedication to education
Sound power testing—performed at 1/3 Octave band from 50
to 10,000 Hz, in accordance with AMCA Standard 300.
Airflow testing—conducted up to 60,000 cfm at 3” of static
pressure (Pst) or 30,000 cfm at 10” of static pressure (Pst), in
accordance with AMCA Standard 210.

Use of Toilet Exhaust for Energy Recovery Purposes has generally been prohibited.  However with the use of Renewaire Sta...
10/20/2014

Use of Toilet Exhaust for Energy Recovery Purposes has generally been prohibited. However with the use of Renewaire Static Core Energy Recovery units that provide complete separation of Supply and Exhaust Air streams, energy recovery is possible. This project located in Yonkers, uses the waste energy from the bathroom exhaust to temper the outside air provided to the corridor spaces. This offers substantial reduction in cost associated with heating the fresh air supplied to the building.

HVAC Technologies USA provides design and equipment solution for the First GREEN Car Dealership in Westchester.  Combini...
10/09/2014

HVAC Technologies USA provides design and equipment solution for the First GREEN Car Dealership in Westchester. Combining Packaged Roof Top Units with Ducted Energy Recovery Units provides a cost effective solution with payback periods under 5 years.

Address

PO BOX 282
Mamaroneck, NY
10523

Opening Hours

Monday 8am - 5pm
Tuesday 8am - 5pm
Wednesday 8am - 5pm
Thursday 8am - 5pm
Friday 8am - 5pm
Saturday 8am - 6pm
Sunday 8am - 5pm

Telephone

(914)3337500

Alerts

Be the first to know and let us send you an email when HVAC Technologies USA, Inc. posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to HVAC Technologies USA, Inc.:

Share