Henrich Electronics

Henrich Electronics Excellence in Industrial Ethernet Switches and Wireless Communications. Some of which include CBTC, TCMS and P*S.

“Founded 30 years ago, the early Henrich team participated in the founding of the USA Industrial Ethernet Association (UIEA). For over 15 years since, our team has been developing and supplying on-board control & communications, Ethernet solutions. With over 2,000 Industrial Ethernet products to choose from, we guarantee there is a solution for your specific application. Our products are EN50155 certified (with MTBF of up to 50 years), IEC22163 certified, and have zero tolerance for defect.”

💬 Is your network ready for the 2026 Smart Factory surge? ➡️ As we look toward 2026, the "Smart Factory" is no longer a ...
02/27/2026

💬 Is your network ready for the 2026 Smart Factory surge?

➡️ As we look toward 2026, the "Smart Factory" is no longer a buzzword—it’s a massive expansion of high-density automation. More sensors, 4K inspection cameras, and AI-driven PLCs mean your network traffic is about to increase.

What this means for your infrastructure:

✅ The Need for Speed: Standard 100M switches are becoming bottlenecks. Gigabit speeds are now a requirement to handle increased data loads.

✅ Zero-Downtime Reliability: With more devices connected, a single failure can halt an entire line. Redundancy protocols like ERPS and RSTP are critical for sub-50ms recovery.

✅ Environmental Resilience: Automation is moving closer to the "edge," where heat, vibration, and EMI are constant threats.

Our rugged industrial switches are engineered specifically for these high-density environments, ensuring that as your factory gets smarter, your connection stays stronger.💡

Check out the link to learn more: https://predision.com/detail?id=104

Stop replacing your legacy machines—start connecting them.  Many industrial facilities still rely on high-value legacy e...
02/12/2026

Stop replacing your legacy machines—start connecting them.

Many industrial facilities still rely on high-value legacy equipment that communicates via RS-232, RS-485, or RS-422. The challenge? These machines can’t "talk" to your modern Ethernet-based management system.

How to bridge the gap in 3 steps:

🔌 Connect: Plug your serial device into the Predision Serial Device Server.

🔄 Convert: The server converts serial data into TCP/IP packets.

🌐 Communicate: Access your machine data from anywhere on the network via a virtual COM port or IP address.

✅ Why it matters: You gain real-time monitoring and data collection without the capital expense of replacing perfectly functional machinery.

🔗 Click here to learn more about our Serial Device Server: https://predision.com/detail/?id=297

Rugged, Reliable, and Ready for the Plant Floor: Meet the Predision RS-232 to RS-485 Converter. ⚙️ When you're bridging ...
02/05/2026

Rugged, Reliable, and Ready for the Plant Floor: Meet the Predision RS-232 to RS-485 Converter. ⚙️

When you're bridging legacy equipment with modern industrial networks, you can't afford a weak link. Our RS-232 to RS-485 Converter (HESC-T-011) is engineered specifically for the environments where consumer-grade gear fails.

Why it’s a Predision MVP:

🌡️ Extreme Temperature Resilience: Operates flawlessly from -25°C to 70°C. Whether it’s an unconditioned warehouse or a high-heat manufacturing cell, the data keeps flowing.

⚡ Industrial-Grade Protection: Features ±15KV ESD Protection and 600W Surge Protection on the RS-485 port. It’s built to survive the electrical noise and voltage spikes common in industrial settings.

✅ High-Speed Versatility: Supports a wide range of baud rates from 300 to 115,200 bps, making it compatible with everything from older sensors to modern PLCs.

The Networking Engineer's Solution:

The Challenge: A networking engineer needs to pull data from a legacy CNC machine located 800 feet away from the control room. The machine only has an RS-232 port (limited to 50ft), and the cable path runs directly alongside high-voltage motor lines that create significant electrical interference.

The Predision Fix: By placing the converter at the machine, the engineer converts the signal to RS-485. This allows the data to travel the full 800 feet over a simple twisted-pair cable. Thanks to the 600W surge and ESD protection, the engineer doesn't have to worry about the nearby motors "frying" the serial ports. It’s a low-cost, high-reliability fix that avoids a total system overhaul.

Want to learn more? See the full specs here:

https://predision.com/detail/?id=90

The Future of Factories is Here: Why Predictive Maintenance is Reshaping Industrial Ethernet. Industry 4.0 isn't just a ...
02/04/2026

The Future of Factories is Here: Why Predictive Maintenance is Reshaping Industrial Ethernet.

Industry 4.0 isn't just a buzzword anymore—it's a critical shift. One of the most impactful trends we're seeing gain massive traction is Predictive Maintenance (PdM).

Instead of waiting for machinery to break down (reactive) or performing maintenance on a fixed schedule (preventative), PdM leverages real-time data from sensors to predict when a failure is likely to occur.

This means:
📉 Reduced downtime
💰 Lower maintenance costs
📈 Increased operational efficiency

But here’s the challenge: Getting all that critical sensor data from the factory floor to your analytics platform requires a robust, high-speed, and reliable network infrastructure. This is where Industrial Ethernet becomes the backbone of any successful PdM strategy.

Traditional networks can introduce latency or points of failure, jeopardizing the real-time insights PdM depends on. At Predision, we understand these demands. Our managed Industrial Ethernet switches, for example, are designed to handle the high data volumes and harsh environments of industrial settings, ensuring your PdM sensors communicate flawlessly.

When you're building your next-gen smart factory, remember that reliable data transmission isn't just a convenience—it's the foundation of true predictive power.

Visit our website to learn more about our RS-232 to RS-485 Converter: https://predision.com/detail/?id=90

Stop letting 50ft cable limits slow down your data. 🔌 Did you know that standard RS-232 signals usually top out at about...
02/03/2026

Stop letting 50ft cable limits slow down your data. 🔌

Did you know that standard RS-232 signals usually top out at about 50 feet? In a sprawling warehouse or a multi-story chemical plant, that just doesn't cut it. The solution? Converting to RS-485.

Our RS-232 to RS-485 Converter (HESC-T-011) acts as a high-speed translator for your industrial machines. Here’s why it’s a "must-have" for your toolkit:

✅ Go the Distance: Extends your data transmission from a measly 50ft to over 4,000 feet (1.2km).

✅ Network Scaling: Connect up to 256 modules in a single RS-485 network without needing a repeater.

✅ Rugged Protection: Built-in 3000V optical isolation protects your expensive host controller from ground loops and surges.

✅ Zero-Lag Switching: Features "AutoPro" technology for automatic baud rate switching (300 to 115200 bps)—no software drivers required.

How to use it: Simply connect your RS-232 host (like a PC or PLC) to the input, and use the terminal blocks to run a simple twisted-pair wire to your remote devices. It’s a plug-and-play fix for long-range industrial communication.

Check out the Predision website to learn more about our RS-232 to RS-485 Converter: https://predision.com/detail/?id=90

And be sure to check out our brand new Predision page:
https://www.facebook.com/PredisionLLC/

Address

Norwalk, CT
60850

Alerts

Be the first to know and let us send you an email when Henrich Electronics posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Henrich Electronics:

Shortcuts

Share