DML Mechanical Heating and Cooling Solutions

Call Directions Website

DML Mechanical Heating and Cooling Solutions HVAC contractor for Utah builders & GCs. Residential & commercial new construction: ductwork, gas piping, equipment, start-up & service. Ogden to Provo.

Licensed B100/S350, BBB A+. (385) 307-8871 bout DML Mechanical

Welcome to DML Mechanical! We are your trusted HVAC experts, dedicated to providing top-notch heating and cooling solutions for residential and commercial properties. With years of experience and a commitment to excellence, we offer a wide range of services to ensure your comfort all year round.

Our Services:

Heating Services: Installation, maintenance, and repair of heating systems.
Cooling Services: Installation, maintenance, and repair of cooling systems.
HVAC Installation: Comprehensive HVAC system installation for new constructions and replacements.
HVAC Maintenance: Preventive maintenance plans to keep your systems running efficiently.
Emergency Services: 24/7 emergency services to address any urgent HVAC issues.
Why Choose Us?
At DML Mechanical, we pride ourselves on our expertise, reliability, and customer satisfaction. Our team of skilled technicians is dedicated to delivering high-quality service with a focus on efficiency and safety. We use the latest technology and industry best practices to provide solutions that meet your specific needs.

Connect with Us:
Stay updated with our latest projects, special offers, and expert tips on HVAC maintenance by following our page. Have questions or need a service? Contact us directly through our page or visit our website at www.dmlmechanical.com.

11/05/2026

Metal pipe or plastic pipe on a gas appliance? The builder doesn't pick it. The appliance does.

The metal pipes here are Type B gas vents, labeled for each unit and running straight up their chase.

The white pipes are PVC intake and exhaust on a high-efficiency furnace. Plastic venting is only allowed when the appliance is listed for it, and the manufacturer's instructions have to name the specific plastic pipe (IRC 2021 G2427.4.1).

Why it matters to you: the pipe type changes the chase size and the wall or roof penetrations. Ask your HVAC sub before you frame.

Never cut a truss to fit a duct.1. Cuts, notches and bored holes in trusses, I-joists, glulam, CLT and structural compos...
11/04/2026

Never cut a truss to fit a duct.
1. Cuts, notches and bored holes in trusses, I-joists, glulam, CLT and structural composite lumber are prohibited (IRC 2021 R502.8.2 for floors, R802.7.2 for roofs and ceilings).
2. The only ways around it: the manufacturer's recommendations allow it, or a registered design professional designed the member for that cut.
3. Our practice: lay out the duct route with the truss layout, so trunks and branches run through the open webs instead of through the wood.
Save this and send it to your framer.

11/03/2026

The unit is running. So why put a meter on it? Because step one of every electrical check is proving your meter works.

Live-dead-live (NFPA 70E 120.6):
1. Test your meter on a known live source.
2. Shut it off and test the equipment for zero volts.
3. Test the meter on the live source again.

Why it matters: a stopped motor isn't proof the power is off. A belt-drive blower can keep spinning after shutoff, and a mislabeled breaker or a second feed can leave voltage on the leads. OSHA 29 CFR 1910.333(b)(2)(iv)(B) requires a qualified person to verify with test equipment that parts are de-energized.

Builders and GCs: make test-before-touch the rule for every trade on site.

11/02/2026

Putting a furnace or water heater in the garage? Height matters.

IRC 2021 M1307.3: in a garage, an appliance's ignition source must be at least 18 in. above the floor, unless the appliance is listed as flammable-v***r-ignition resistant.

M1307.3.1: where a vehicle could hit the appliance, it needs an approved barrier.

Plan the platform and the barrier in the garage layout, not after the slab.

11/02/2026

Every vent through an exterior wall has a minimum distance from windows, doors and the ground.

IRC 2021 G2427.8, direct-vent gas appliances, clearance to a window or door that opens:
• 6 in. up to 10,000 Btu/h
• 9 in. up to 50,000 Btu/h
• 12 in. up to 150,000 Btu/h

Same section: 12 in. above grade, and 10 ft horizontally from a mechanical air intake (or 3 ft above it). Terminals that aren't direct-vent: 4 ft below or beside an opening, 1 ft above.

Lay out terminations with the architect before the siding and stone go on.

11/01/2026

Locking caps on the refrigerant ports: required in Utah? It depends on the building.

Homes: Utah deleted IRC M1411.9, the locking-cap requirement (Utah Code 15A-3-203(8)).

Commercial: IMC 2024 Section 1101.9 still requires locking-type, tamper-resistant caps on outdoor refrigerant access ports.

Locking caps still make sense on any unit people can reach. On a house, though, they're a choice, not an inspection item.

Confirm with your code official.

11/01/2026

Build a tight house in Utah and fresh air stops being optional.

Utah's revised IRC energy chapter (R1104.1.3, in force since July 1, 2026): a home that tests at 3 ACH50 or less, or isn't tested at all, needs whole-house mechanical ventilation per IRC M1505.

An ERV is one way to provide it: fresh air comes in, stale air goes out, and the two streams exchange heat and moisture on the way. It needs four duct connections, floor space and service access.

Choose the ventilation system at design, not at drywall. Right at 3.0 ACH50? Confirm with your code official.

10/31/2026

Sweating copper inside a wall is a leak nobody piped.

IRC 2021 M1411.6: refrigerant suction lines need insulation of at least R-3, with a v***r permeance of 0.05 perm or less.

Why: the suction line runs cold. Without insulation it condenses water inside walls and ceilings, and it loses capacity along the way.

Builders: look for continuous insulation on the suction line at rough-in, especially at the bores and where it leaves the building.

10/31/2026

There's a small fitting on the gas line at most furnaces, and the code requires it.

IRC 2021 G2419.4: a sediment trap goes on the gas supply at the appliance, downstream of the appliance shutoff valve, unless the appliance has one built in. It keeps debris and moisture in the line away from the gas controls.

Not required on illuminating appliances, ranges, clothes dryers, decorative appliances for vented fireplaces, gas fireplaces and outdoor grills.

Builders: it's a quick check at gas rough-in and again at final.

10/30/2026

High-efficiency furnaces vent through plastic pipe, and the furnace manual is the rulebook.

IRC 2021 G2427.4.1: plastic vent pipe must be installed per the appliance manufacturer's instructions. That's where the pipe material, sizes, maximum lengths, fittings and termination come from.

G2427.9: condensate from Category II and IV vents has to be collected and disposed of. Where a blocked drain would cause damage, a Category IV appliance needs an auxiliary pan unless it shuts itself off (G2404.10).

Builders: keep the furnace manual on site for the rough-in inspection, and plan where the condensate goes.

Address

174 E Polaris Drive
Saratoga Springs, NY
84045

Opening Hours

Monday 7am - 6pm
Tuesday 7am - 6pm
Wednesday 7am - 5pm
Thursday 7am - 5pm
Friday 7am - 5pm
Saturday 9am - 5pm

Telephone

+13854613757

Alerts

Be the first to know and let us send you an email when DML Mechanical Heating and Cooling Solutions posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Share

Nearby engineering companies