Fox Tapping, Inc.

Fox Tapping, Inc. Piping services throughout the mid-Atlantic region since 1978.

We performed a through the valve change out under pressure this week. The customer had a faulty 3” schedule 80 PVC valve...
02/06/2026

We performed a through the valve change out under pressure this week. The customer had a faulty 3” schedule 80 PVC valve that they wanted to replace without draining a multi-million gallon tank.

20” line stop on dip water main, so the customer could install new piping for a new water storage tank.
12/11/2025

20” line stop on dip water main, so the customer could install new piping for a new water storage tank.

Couple 22”x20” taps on carbon steel pipe domestic water 180 psi, test pressure 270 psi.
11/08/2025

Couple 22”x20” taps on carbon steel pipe domestic water 180 psi, test pressure 270 psi.

Couple recent projects, here and there with great people and partnerships
03/28/2025

Couple recent projects, here and there with great people and partnerships

4”x2” tap on HDPE pipe DR 11 pipe water main with electro-fusion tee and corporation stop.
03/05/2025

4”x2” tap on HDPE pipe DR 11 pipe water main with electro-fusion tee and corporation stop.

Saturday’s project 2 - 6” freezes.
03/03/2025

Saturday’s project 2 - 6” freezes.

Friday, last project of the week. Installing 10” insert valve.
02/15/2025

Friday, last project of the week. Installing 10” insert valve.

1 - 12” bagstop and 1 - 12” line stop for valve change out.
02/13/2025

1 - 12” bagstop and 1 - 12” line stop for valve change out.

Customer requested they needed 1 - 8” line stop, couple 2” taps and some cold cutting to relocate an existing 8” 40 psi ...
12/14/2024

Customer requested they needed 1 - 8” line stop, couple 2” taps and some cold cutting to relocate an existing 8” 40 psi steel natural gas line at a local manufacturer without having to shut down production.

Some recent line stop projects for some valve change outs.
11/09/2024

Some recent line stop projects for some valve change outs.

Freezing 2” copper heat pump lines at a senior living facility so the customer could install new valves at several locat...
11/01/2024

Freezing 2” copper heat pump lines at a senior living facility so the customer could install new valves at several locations for a renovation project.

A few weeks ago we performed 2 - 3” line stops with a 1” bypass on a copper water main to maintain service to three buil...
09/12/2024

A few weeks ago we performed 2 - 3” line stops with a 1” bypass on a copper water main to maintain service to three buildings at a college while the existing copper main was relocated for a new culvert/bridge/road project.

Address

1112 Nursery Road
Wrightsville, PA
17368

Alerts

Be the first to know and let us send you an email when Fox Tapping, Inc. posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Fox Tapping, Inc.:

Share