Differential pressure transmmitter for low ranges
Model PRE-50G
Manufacturer: Aplisens
Application
The PRE-50G transmitter is applicable to gases, to the measurements of their pressure, underpressure and differential pressure. Typical applications include the measurement of blast pressure, chimney draughts or pressure / underpressure in furnace chambers. IP protection IP65.
Technical data
Any measuring range 250 Pa ÷ 20 kPa
Histeresis, repeatability 0,05% to 0,25%
depend on setting range
Thermal compensation range 5 ÷ 50°C
Operating temperature range -25 ÷ 80°C
Standard measuring range : 0...250; 0...500 Pa; 0...2; 0...5; 0...10 kPa; -150...150; -250...250 Pa; -0,5...0,5; -1...1; -2,5...2,5; -5...5; -10...10 kPa
Output signal: 4 ÷ 20 mA two wire transmission
0 ÷ 10 V three wire transmission
Power supply: 10…36 VDC two wire transmission
13…39 VDC three wire transmission
Housing material 0H18N9 (SS304)
Adapters material C - SS316Ti
M20×1,5/_6×1 – brass
Valve manifolds SS316

For more info refer to: https://ctmarkvn.com/aplisens




-50G

Differential pressure transmmitter for low ranges Model PRE-50GManufacturer: AplisensApplicationThe PRE-50G transmitter ...
17/04/2026

Differential pressure transmmitter for low ranges
Model PRE-50G
Manufacturer: Aplisens
Application
The PRE-50G transmitter is applicable to gases, to the measurements of their pressure, underpressure and differential pressure. Typical applications include the measurement of blast pressure, chimney draughts or pressure / underpressure in furnace chambers. IP protection IP65.
Technical data
Any measuring range 250 Pa ÷ 20 kPa
Histeresis, repeatability 0,05% to 0,25%
depend on setting range
Thermal compensation range 5 ÷ 50°C
Operating temperature range -25 ÷ 80°C
Standard measuring range : 0...250; 0...500 Pa; 0...2; 0...5; 0...10 kPa; -150...150; -250...250 Pa; -0,5...0,5; -1...1; -2,5...2,5; -5...5; -10...10 kPa
Output signal: 4 ÷ 20 mA two wire transmission
0 ÷ 10 V three wire transmission
Power supply: 10…36 VDC two wire transmission
13…39 VDC three wire transmission
Housing material 0H18N9 (SS304)
Adapters material C - SS316Ti
M20×1,5/_6×1 – brass
Valve manifolds SS316

For more info refer to: https://ctmarkvn.com/aplisens




-50G

For more info refer to: ctmarkvn.com/wika-temperature         .063  .100
16/04/2026

For more info refer to: ctmarkvn.com/wika-temperature








.063 .100

Gas-actuated thermometer
Model TGT70
Manufacturer: WIKA
Measurement principle: Bourdon tube system
Nominal size in mm: 63 [2 ½"]; 100 [4"]
Instrument version
Version H
63 [2 ½"]: Lower mount (radial) Instrument with remote capillary, rear surface mounting fl**ge.
100 [4"] Lower mount (radial) Instrument with remote capillary, rear surface mounting fl**ge.
Version M
63 [2 ½"]: Lower mount (radial) Instrument with remote capillary, instrument mounting bracket
100 [4"]: Lower mount (radial) Instrument with remote capillary, instrument mounting bracket
Version B
63 [2 ½"] Back mount (axial) Instrument with remote capillary, triangular profile ring and mounting clamp
Version R
100 [4"] Lower mount (radial) Direct connection without remote capillary
Connection design
1 Plain stem (without thread)
2 Male nut
3 Union nut
4 Compression fitting (sliding on stem)
5 Union nut and loose threaded connection
6 Compression fitting (sliding on remote capillary)
Further connection designs on request
Unit (scale range): °C; °F; °C/°F (dual scale)
Process connection: Plain
Indication accuracy: Class 2, EN 13190
Stem diameter: 8 mm [0.31 in]
Window: Laminated safety glass
Active probe length: Depending on Ø d and scale range
Remote capillary
Ø 2 mm [0.08 in], stainless steel 1.4571, bending radius no less than 6 mm [0.24 in]
Length to customer specification (max. 10 m [32.81 ft])
Connection location: Lower mount (radial); Back mount (axial)
Remote capillary mounting: Take care that the mounting is free from vibration
Process connection: Stainless steel 1.4571
Stem: Stainless steel 1.4571
Case, bayonet ring: Stainless steel
Dial: Plastic, white, black lettering
Dial sticker: Plastic, white with logo
Pointer: Aluminium, black
Fill fluid of measuring system: Xylene; Silicone oil
Thermowell/protection tube: Without; Per DIN; To customer specification
Ingress protection per IEC/EN 60529: IP65
Permissible temperatures
Ambient temperature at case: Max. 0 ... 40 °C [32 ... 104 °F] (others on request)
Storage and transport per EN 13190: -20 ... +60 °C [-4 ... +140 °F]
Permissible operating pressure at the stem: Max. 25 bar [362.59 psi], static
Electrical connection: Lateral cable socket; Cable gland; Cable outlet; M12 connector
​​​​​​​Voltage signal
For Us = DC 5 V, ratiometric: 0.5 … 4.5 V
For Us = DC 12 … 32 V
not ratiometric (NS 100 [4"] only): 0.5 … 4.5 V
Current output: 4 … 20 mA, 2-wire
Accuracy of electrical output signal: Mechanical ±1 % of measuring span
Supply voltage US: DC 5 V / DC 12 … 32 V
Electromagnetic compatibility: Per test standards EN 61000-4-6 / EN 61000-4-3
Output signal and permissible load
Voltage output (3-wire) RA > 5 kΩ
Current output (2-wire) 4 ... 20 mA RA ≤ (USIG - 10 V) / 0.02 A with RA in Ω and USIG in DC V

For more info refer to: ctmarkvn.com/wika-temperature








.063 .100

Gas-actuated thermometerModel TGT70Manufacturer: WIKAMeasurement principle: Bourdon tube systemNominal size in mm: 63 [2...
16/04/2026

Gas-actuated thermometer
Model TGT70
Manufacturer: WIKA
Measurement principle: Bourdon tube system
Nominal size in mm: 63 [2 ½"]; 100 [4"]
Instrument version
Version H
63 [2 ½"]: Lower mount (radial) Instrument with remote capillary, rear surface mounting fl**ge.
100 [4"] Lower mount (radial) Instrument with remote capillary, rear surface mounting fl**ge.
Version M
63 [2 ½"]: Lower mount (radial) Instrument with remote capillary, instrument mounting bracket
100 [4"]: Lower mount (radial) Instrument with remote capillary, instrument mounting bracket
Version B
63 [2 ½"] Back mount (axial) Instrument with remote capillary, triangular profile ring and mounting clamp
Version R
100 [4"] Lower mount (radial) Direct connection without remote capillary
Connection design
1 Plain stem (without thread)
2 Male nut
3 Union nut
4 Compression fitting (sliding on stem)
5 Union nut and loose threaded connection
6 Compression fitting (sliding on remote capillary)
Further connection designs on request
Unit (scale range): °C; °F; °C/°F (dual scale)
Process connection: Plain
Indication accuracy: Class 2, EN 13190
Stem diameter: 8 mm [0.31 in]
Window: Laminated safety glass
Active probe length: Depending on Ø d and scale range
Remote capillary
Ø 2 mm [0.08 in], stainless steel 1.4571, bending radius no less than 6 mm [0.24 in]
Length to customer specification (max. 10 m [32.81 ft])
Connection location: Lower mount (radial); Back mount (axial)
Remote capillary mounting: Take care that the mounting is free from vibration
Process connection: Stainless steel 1.4571
Stem: Stainless steel 1.4571
Case, bayonet ring: Stainless steel
Dial: Plastic, white, black lettering
Dial sticker: Plastic, white with logo
Pointer: Aluminium, black
Fill fluid of measuring system: Xylene; Silicone oil
Thermowell/protection tube: Without; Per DIN; To customer specification
Ingress protection per IEC/EN 60529: IP65
Permissible temperatures
Ambient temperature at case: Max. 0 ... 40 °C [32 ... 104 °F] (others on request)
Storage and transport per EN 13190: -20 ... +60 °C [-4 ... +140 °F]
Permissible operating pressure at the stem: Max. 25 bar [362.59 psi], static
Electrical connection: Lateral cable socket; Cable gland; Cable outlet; M12 connector
​​​​​​​Voltage signal
For Us = DC 5 V, ratiometric: 0.5 … 4.5 V
For Us = DC 12 … 32 V
not ratiometric (NS 100 [4"] only): 0.5 … 4.5 V
Current output: 4 … 20 mA, 2-wire
Accuracy of electrical output signal: Mechanical ±1 % of measuring span
Supply voltage US: DC 5 V / DC 12 … 32 V
Electromagnetic compatibility: Per test standards EN 61000-4-6 / EN 61000-4-3
Output signal and permissible load
Voltage output (3-wire) RA > 5 kΩ
Current output (2-wire) 4 ... 20 mA RA ≤ (USIG - 10 V) / 0.02 A with RA in Ω and USIG in DC V

For more info refer to: ctmarkvn.com/wika-temperature








.063 .100

For more info refer to: ctmarkvn.com/rosemount-emerson
15/04/2026

For more info refer to: ctmarkvn.com/rosemount-emerson





Temperature Transmitter
Model 644
Manufacturer: Rosemount (Emerson)
Specifications
* Input: Dual and single sensor capability with universal sensor inputs (RTD, T/C, mV, ohms)
* Output Signal: 4-20 mA /HART™ protocol, FOUNDATION™ fieldbus protocol, PROFIBUS™ PA protocol
* Housing: Field mount, DIN A head mount or rail mount
* Display/Interface: LCD Display, LCD Display with Local Operator Interface (LOI), or LED
* Diagnostics: Basic diagnostics, Hot Backup™ capability, sensor drift alert, thermocouple degradation, min/max tracking
* Calibration Options: Transmitter-sensor matching (Callendar-Van Dusen constants), 5-point calibration
* Certifications/Approvals: SIL 2/3 certified to IEC 61508 by an independent 3rd party, hazardous location, marine type, see full specs for complete list of certifications
Features
* Extremely versatile temperature transmitter available in HART™, FOUNDATION™ Fieldbus or PROFIBUS™ protocols
* Diverse mounting configurations including head, field or rail mount with many enclosure options
* LOI option eliminates the need for special configuration tools (i.e. field communicator) for ease-of-use
* Transmitter-sensor matching with Callendar-Van Dusen constants reduces total measurement error
* Hot Backup™ capability and sensor drift alert with dual sensors ensure measurement integrity
* Thermocouple degradation diagnostic monitors thermocouple health to detect degradation before failure
* Minimum and maximum temperature tracking observes temperature extremes for easy troubleshooting
* Device dashboards provide easy interface for simplified device configuration and diagnostic troubleshooting

For more info refer to: ctmarkvn.com/rosemount-emerson





Temperature TransmitterModel 644Manufacturer: Rosemount (Emerson)Specifications* Input: Dual and single sensor capabilit...
15/04/2026

Temperature Transmitter
Model 644
Manufacturer: Rosemount (Emerson)
Specifications
* Input: Dual and single sensor capability with universal sensor inputs (RTD, T/C, mV, ohms)
* Output Signal: 4-20 mA /HART™ protocol, FOUNDATION™ fieldbus protocol, PROFIBUS™ PA protocol
* Housing: Field mount, DIN A head mount or rail mount
* Display/Interface: LCD Display, LCD Display with Local Operator Interface (LOI), or LED
* Diagnostics: Basic diagnostics, Hot Backup™ capability, sensor drift alert, thermocouple degradation, min/max tracking
* Calibration Options: Transmitter-sensor matching (Callendar-Van Dusen constants), 5-point calibration
* Certifications/Approvals: SIL 2/3 certified to IEC 61508 by an independent 3rd party, hazardous location, marine type, see full specs for complete list of certifications
Features
* Extremely versatile temperature transmitter available in HART™, FOUNDATION™ Fieldbus or PROFIBUS™ protocols
* Diverse mounting configurations including head, field or rail mount with many enclosure options
* LOI option eliminates the need for special configuration tools (i.e. field communicator) for ease-of-use
* Transmitter-sensor matching with Callendar-Van Dusen constants reduces total measurement error
* Hot Backup™ capability and sensor drift alert with dual sensors ensure measurement integrity
* Thermocouple degradation diagnostic monitors thermocouple health to detect degradation before failure
* Minimum and maximum temperature tracking observes temperature extremes for easy troubleshooting
* Device dashboards provide easy interface for simplified device configuration and diagnostic troubleshooting

For more info refer to: ctmarkvn.com/rosemount-emerson





Expansion thermometer Model 70Manufacturer: WIKAStandard versionMeasuring principle: Bourdon tube systemNominal size in ...
14/04/2026

Expansion thermometer
Model 70
Manufacturer: WIKA
Standard version
Measuring principle: Bourdon tube system
Nominal size in mm: 63, 100, 160
Design of connection
1 Plain stem (without thread)
2 Male nut
3 Union nut
4 Compression fitting (sliding on stem)
5 Union nut with fitting
6 Compression fitting (sliding on capillary)
Instrument version and type of mounting
B Instruments with capillary; centre back mount triangular bezel with bracket
H Instruments with capillary; lower mount (radial) surface mounting fl**ge
M Instruments with capillary; lower mount (radial) surface mounting bracket, aluminium die cast
V Instruments with capillary; back mount 1) panel mounting fl**ge
A Back mount 1), fix plain stem, threaded connection or thermowell
R Lower mount (radial), fix plain stem, threaded connection or thermowell
S Back mount 1), fix plain stem, threaded connection or thermowell; swivelling approx. 90 ∢°
1) eccentric; NS 63: centric
Fill medium measuring system: Xylol or silicon oil
Accuracy class: Class 2
Rated operating ranges and conditions: EN 13190
Capillary entry: Lower or back
Case: Stainless steel
Bezel ring: Stainless steel
Connection: Stainless steel 1.4571
Capillary: Length to customer specifications (max. 10 m), Ø 2 mm, stainless steel 1.4571, bending radius not less than 6 mm

Stem: Ø 8 mm, stainless steel 1.4571
Active length of sensor: Depending on Ø d and scale range
Dial: Aluminium, white, black lettering
Pointer: Aluminium, black
Window
NS 100, 160: Instrument glass
NS 63: Transparent plastic
Temperature limits for storage and transport
-50 … +70 °C (EN 13190) without liquid damping
-20 … +60 °C (EN 13190) with food-compatible liquid damping
-50 … +60 °C (EN 13190) with liquid damping
Ambient temperature limit at the case: 0 … 40 °C max. (others on request)
Pressure rating of stem: 25 bar max., static
Ingress protection: IP 65 per EN 60529 / IEC 529
Options
* Scale range °F, °C/°F (dual scale)
* Laminated safety glass, clear plastic
* Ambient temperature compensation
* Accuracy class 1.0
* Thermowell per DIN or to customer specification
* Surface mounting bracket from other materials and in other lengths (A)
* Liquid filling case with
NS 63: Model X70.53.063
NS 100: Model X70.53.100
NS 160: Model X70.53.160
Filling medium: glycerine
* Spiral protecting hose stainless steel
* Designs per DIN EN ISO 13485, medical applications on request
* Model 70 with micro switch see WIKA data sheet TV 28.01
* Stem diameter 6, 10 mm

For more info refer to: ctmarkvn.com/wika-temperature








.50 .53 .50 .53 .50 .53 .50 .53

For more info refer to: ctmarkvn.com/wika-temperature         .50  .53  .50  .53  .50  .53  .50  .53
14/04/2026

For more info refer to: ctmarkvn.com/wika-temperature








.50 .53 .50 .53 .50 .53 .50 .53

Expansion thermometer
Model 70
Manufacturer: WIKA
Standard version
Measuring principle: Bourdon tube system
Nominal size in mm: 63, 100, 160
Design of connection
1 Plain stem (without thread)
2 Male nut
3 Union nut
4 Compression fitting (sliding on stem)
5 Union nut with fitting
6 Compression fitting (sliding on capillary)
Instrument version and type of mounting
B Instruments with capillary; centre back mount triangular bezel with bracket
H Instruments with capillary; lower mount (radial) surface mounting fl**ge
M Instruments with capillary; lower mount (radial) surface mounting bracket, aluminium die cast
V Instruments with capillary; back mount 1) panel mounting fl**ge
A Back mount 1), fix plain stem, threaded connection or thermowell
R Lower mount (radial), fix plain stem, threaded connection or thermowell
S Back mount 1), fix plain stem, threaded connection or thermowell; swivelling approx. 90 ∢°
1) eccentric; NS 63: centric
Fill medium measuring system: Xylol or silicon oil
Accuracy class: Class 2
Rated operating ranges and conditions: EN 13190
Capillary entry: Lower or back
Case: Stainless steel
Bezel ring: Stainless steel
Connection: Stainless steel 1.4571
Capillary: Length to customer specifications (max. 10 m), Ø 2 mm, stainless steel 1.4571, bending radius not less than 6 mm

Stem: Ø 8 mm, stainless steel 1.4571
Active length of sensor: Depending on Ø d and scale range
Dial: Aluminium, white, black lettering
Pointer: Aluminium, black
Window
NS 100, 160: Instrument glass
NS 63: Transparent plastic
Temperature limits for storage and transport
-50 … +70 °C (EN 13190) without liquid damping
-20 … +60 °C (EN 13190) with food-compatible liquid damping
-50 … +60 °C (EN 13190) with liquid damping
Ambient temperature limit at the case: 0 … 40 °C max. (others on request)
Pressure rating of stem: 25 bar max., static
Ingress protection: IP 65 per EN 60529 / IEC 529
Options
* Scale range °F, °C/°F (dual scale)
* Laminated safety glass, clear plastic
* Ambient temperature compensation
* Accuracy class 1.0
* Thermowell per DIN or to customer specification
* Surface mounting bracket from other materials and in other lengths (A)
* Liquid filling case with
NS 63: Model X70.53.063
NS 100: Model X70.53.100
NS 160: Model X70.53.160
Filling medium: glycerine
* Spiral protecting hose stainless steel
* Designs per DIN EN ISO 13485, medical applications on request
* Model 70 with micro switch see WIKA data sheet TV 28.01
* Stem diameter 6, 10 mm

For more info refer to: ctmarkvn.com/wika-temperature








.50 .53 .50 .53 .50 .53 .50 .53

Expansion thermometerModel 70Manufacturer: WIKAStandard versionMeasuring principle: Bourdon tube systemNominal size in m...
14/04/2026

Expansion thermometer
Model 70
Manufacturer: WIKA
Standard version
Measuring principle: Bourdon tube system
Nominal size in mm: 63, 100, 160
Design of connection
1 Plain stem (without thread)
2 Male nut
3 Union nut
4 Compression fitting (sliding on stem)
5 Union nut with fitting
6 Compression fitting (sliding on capillary)
Instrument version and type of mounting
B Instruments with capillary; centre back mount triangular bezel with bracket
H Instruments with capillary; lower mount (radial) surface mounting fl**ge
M Instruments with capillary; lower mount (radial) surface mounting bracket, aluminium die cast
V Instruments with capillary; back mount 1) panel mounting fl**ge
A Back mount 1), fix plain stem, threaded connection or thermowell
R Lower mount (radial), fix plain stem, threaded connection or thermowell
S Back mount 1), fix plain stem, threaded connection or thermowell; swivelling approx. 90 ∢°
1) eccentric; NS 63: centric
Fill medium measuring system: Xylol or silicon oil
Accuracy class: Class 2
Rated operating ranges and conditions: EN 13190
Capillary entry: Lower or back
Case: Stainless steel
Bezel ring: Stainless steel
Connection: Stainless steel 1.4571
Capillary: Length to customer specifications (max. 10 m), Ø 2 mm, stainless steel 1.4571, bending radius not less than 6 mm

Stem: Ø 8 mm, stainless steel 1.4571
Active length of sensor: Depending on Ø d and scale range
Dial: Aluminium, white, black lettering
Pointer: Aluminium, black
Window
NS 100, 160: Instrument glass
NS 63: Transparent plastic
Temperature limits for storage and transport
-50 … +70 °C (EN 13190) without liquid damping
-20 … +60 °C (EN 13190) with food-compatible liquid damping
-50 … +60 °C (EN 13190) with liquid damping
Ambient temperature limit at the case: 0 … 40 °C max. (others on request)
Pressure rating of stem: 25 bar max., static
Ingress protection: IP 65 per EN 60529 / IEC 529
Options
* Scale range °F, °C/°F (dual scale)
* Laminated safety glass, clear plastic
* Ambient temperature compensation
* Accuracy class 1.0
* Thermowell per DIN or to customer specification
* Surface mounting bracket from other materials and in other lengths (A)
* Liquid filling case with
NS 63: Model X70.53.063
NS 100: Model X70.53.100
NS 160: Model X70.53.160
Filling medium: glycerine
* Spiral protecting hose stainless steel
* Designs per DIN EN ISO 13485, medical applications on request
* Model 70 with micro switch see WIKA data sheet TV 28.01
* Stem diameter 6, 10 mm

For more info refer to: ctmarkvn.com/wika-temperature








.50 .53 .50 .53 .50 .53 .50 .53

For more info refer to: ctmarkvn.com/yokogawa-japan
13/04/2026

For more info refer to: ctmarkvn.com/yokogawa-japan




Digital Remote Sensor (DRS) Differential Pressure SystemModel: EJXC40AManufacturer: YokogawaThe EJXC40A Digital Remote S...
13/04/2026

Digital Remote Sensor (DRS) Differential Pressure System
Model: EJXC40A
Manufacturer: Yokogawa
The EJXC40A Digital Remote Sensor (DRS) transmitter connects two pressure sensors, the master sensor (for high-pressure side) and remote sensor (for low-pressure side) with DRS dedicated communication cable to measure differential pressure. The DP is transmitted via a 4 to 20 mA analog signal. EJXC40A is suitable to measure liquid, gas, or steam flow as well as liquid level, density and pressure.
Key Features
* High performance, high accuracy and high reliability
* Better performance over long capillaries of diaphragm seal system.
* Suitable for level measurement of a tall tank
* DRS cable length (maximum): 45 m
* Signal characterization for various tank types
* Exida SIL 2 / SIL3 Certified

The transmitter outputs differential pressure, using the two transmitters of same model and capsule for primary (high-pressure side) and secondary (low-pressure side) pressure sensors.
When using EJX530A Gauge Pressure Transmitter
Capsule Measurement Span Range
A 2 to 200 kPa −200 to 200 kPa
B 0.01 to 2 MPa −2 to 2 MPa
C 0.05 to 10 MPa −10 to 10 MPa
D 0.35 to 50 MPa −50 to 50 MPa
When using EJX630A Gauge Pressure Transmitter
Capsule Measurement Span Range
A 2 to 200 kPa −200 to 200 kPa
B 0.01 to 2 MPa −2 to 2 MPa
C 0.05 to 10 MPa −10 to 10 MPa
D 0.35 to 70 MPa −70 to 70 MPa

For more info refer to: ctmarkvn.com/yokogawa-japan




For more info refer to: ctmarkvn.com/instrumate                #412
11/04/2026

For more info refer to: ctmarkvn.com/instrumate













#412

Address

119/55A Đường Phan Văn Hùm, Phường Trung Mỹ Tây
Ho Chi Minh City
70000

Alerts

Be the first to know and let us send you an email when Công ty TNHH Công Nghiệp Ctmark VN posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Công ty TNHH Công Nghiệp Ctmark VN:

Share