TAZ Engineering Company Limited

Call Directions Website Contact the business

TAZ Engineering Company Limited We provide Fire Protection, Smoke Control & Mechanical Ventilation Systems

We provide project & design consultancy, engineering services, supply & installation, service & maintenance of fire protection systems and products designed for the protection of high risk, high challenge hazards from Fire in diverse industries.

23/09/2026

FlameSpec™ IR3-CO2L- Triple IR Flame Detector

FlameSpec CO2L- reduced false alarms in presence of hot CO2

The FlameSpec-IR3-CO2L detects liquid and solid hydrocarbon fires where exhaust gases from engines are a challenge for other detectors.

✈️🔥 𝗪𝗵𝗮𝘁 𝗶𝘀 𝘁𝗵𝗲 𝗳𝗶𝗿𝗲 𝗿𝗶𝘀𝗸 𝗻𝗼. 𝟭 𝗶𝗻 𝗵𝗮𝗻𝗴𝗮𝗿𝘀? 🔧 When aircraft are parked in a hangar for maintenance, repair, or storage, ...
05/08/2026

✈️🔥 𝗪𝗵𝗮𝘁 𝗶𝘀 𝘁𝗵𝗲 𝗳𝗶𝗿𝗲 𝗿𝗶𝘀𝗸 𝗻𝗼. 𝟭 𝗶𝗻 𝗵𝗮𝗻𝗴𝗮𝗿𝘀?

🔧 When aircraft are parked in a hangar for maintenance, repair, or storage, they are not usually fueled up. However, a certain amount of fuel can remain. As a result, 𝗺𝗮𝗶𝗻𝘁𝗲𝗻𝗮𝗻𝗰𝗲 𝗮𝗻𝗱 𝗿𝗲𝗽𝗮𝗶𝗿 𝘄𝗼𝗿𝗸𝘀 increase the fire risk due to potential ignition sources.

⚠️ Fires may break out in various places in the hangar. However, the biggest potential ignition source is 𝗯𝗲𝗹𝗼𝘄 𝘁𝗵𝗲 𝗮𝗶𝗿𝗰𝗿𝗮𝗳𝘁’𝘀 𝘄𝗶𝗻𝗴𝘀 as leaking fuel may gather there.

👉 𝗧𝗵𝗲 𝗸𝗲𝘆 𝗲𝗹𝗲𝗺𝗲𝗻𝘁𝘀 𝗼𝗳 𝘀𝘂𝗰𝗰𝗲𝘀𝘀𝗳𝘂𝗹 𝗳𝗶𝗿𝗲 𝗽𝗿𝗼𝘁𝗲𝗰𝘁𝗶𝗼𝗻 𝗶𝗻 𝗵𝗮𝗻𝗴𝗮𝗿𝘀:

• 𝗘𝗮𝗿𝗹𝘆 𝗳𝗶𝗿𝗲 𝗱𝗲𝘁𝗲𝗰𝘁𝗶𝗼𝗻 𝘀𝘆𝘀𝘁𝗲𝗺𝘀 enable the early detection and suppression of fire sources
• 𝗥𝗲𝗺𝗼𝘁𝗲-𝗰𝗼𝗻𝘁𝗿𝗼𝗹𝗹𝗲𝗱 𝗳𝗶𝗿𝗲𝗳𝗶𝗴𝗵𝘁𝗶𝗻𝗴 𝗺𝗼𝗻𝗶𝘁𝗼𝗿𝘀 integrated into the early fire detection system allow pinpoint extinguishing within a defined area for a defined duration: only until no more fire risk exists.
• 𝗦𝘁𝗮𝘁𝗶𝗼𝗻𝗮𝗿𝘆 𝗳𝗼𝗮𝗺 𝗽𝗿𝗼𝗽𝗼𝗿𝘁𝗶𝗼𝗻𝗲𝗿𝘀 reliably supply high-expansion foam generators and extinguishing monitors with premix to generate extinguishing foam.

A FireDos proportioner + fixed foam monitors with foam pipe/deflector can be a very good solution for an aircraft hangar...
04/08/2026

A FireDos proportioner + fixed foam monitors with foam pipe/deflector can be a very good solution for an aircraft hangar, particularly for targeted low-expansion foam application. However, the system needs to be designed around the hangar classification, aircraft size, fuel load, detection philosophy and the applicable edition of NFPA 409, rather than simply selecting monitors by coverage area.

A typical arrangement would be:
Fire water tank → Fire pump → FireDos proportioner → foam solution header → fixed FireDos monitors → foam pipe with deflector → aircraft/hangar risk area

For an aircraft hangar, we would not design this as simply "foam monitors protecting the floor."

We would design it as:
Early detection → rapid targeted foam application → protection of aircraft and under-wing fuel-spill areas → supplementary/automatic foam protection → safe drainage and containment.

That is much more defensible from an engineering standpoint.

And FireDos is particularly relevant because it has an actual aircraft-hangar application reference in which stationary FireDos proportioners supply high-expansion foam generators, as well as a broader aircraft-hangar concept using remote-controlled monitors.

🔥 Understanding Fire Detection Systems–Types of Fire Detectors 🔥Fire detectors are the first line of defense in protecti...
31/07/2026

🔥 Understanding Fire Detection Systems–Types of Fire Detectors 🔥

Fire detectors are the first line of defense in protecting people, assets, and facilities. Choosing the right detector for the right environment is essential for effective fire protection.

A proper understanding of these detectors helps ensure safer and more reliable fire protection systems.

Active Fire Protection Vs Passive Fire Protection Fire safety effectiveness is achieved when both active and passive fir...
01/07/2026

Active Fire Protection Vs Passive Fire Protection

Fire safety effectiveness is achieved when both active and passive fire protection systems work in synergy to protect people, property, and ensure business operations.

High-Pressure Water Mist for Lithium-Ion Battery Protection in Data Centers – Is Pre-Action Really the Best Choice?High-...
29/06/2026

High-Pressure Water Mist for Lithium-Ion Battery Protection in Data Centers – Is Pre-Action Really the Best Choice?

High-pressure (HP) water mist systems are increasingly being proposed to protect lithium-ion battery installations in data centers. This is a positive development, given their proven ability to control and suppress battery fires.

However, one critical concern remains.

In many projects, the system is designed as a pre-action sprinkler system, relying on automatic glass-bulb nozzles that discharge only after the bulb reaches its activation temperature. By the time these nozzles operate, thermal runaway may already be well established, resulting in significant fire growth, off-gassing, and extensive damage.

For lithium-ion battery hazards, a deluge HP water mist system with open nozzles is often a more appropriate solution.

When integrated with an early off-gas detection system, the deluge system can be activated before thermal runaway fully develops. This enables earlier cooling of the battery modules, helping to slow or limit thermal runaway propagation, reduce fire intensity, minimize damage, and provide valuable time for emergency response.

For these reasons, a deluge HP water mist system combined with early off-gas detection generally offers a more effective fire protection strategy than a pre-action system for lithium-ion battery applications—particularly in mission-critical facilities such as data centers.

As lithium-ion energy storage continues to expand, fire protection strategies should prioritize early detection, rapid intervention, and thermal runaway mitigation, rather than relying solely on temperature-activated discharge.

HighPressureWaterMist BatteryEnergyStorage LithiumIonBatteries ThermalRunaway DataCenters FireSuppression FireDetection PerformanceBasedDesign MissionCriticalFacilities EngineeringExcellence

High-Pressure Water Mist for Lithium-Ion Battery Protection in Data Centers – Is Pre-Action Really the Best Choice?High-...
29/06/2026

High-Pressure Water Mist for Lithium-Ion Battery Protection in Data Centers – Is Pre-Action Really the Best Choice?

High-pressure (HP) water mist systems are increasingly being proposed to protect lithium-ion battery installations in data centers. This is a positive development, given their proven ability to control and suppress battery fires.

However, one critical concern remains.

In many projects, the system is designed as a pre-action sprinkler system, relying on automatic glass-bulb nozzles that discharge only after the bulb reaches its activation temperature. By the time these nozzles operate, thermal runaway may already be well established, resulting in significant fire growth, off-gassing, and extensive damage.

For lithium-ion battery hazards, a deluge HP water mist system with open nozzles is often a more appropriate solution.

When integrated with an early off-gas detection system, the deluge system can be activated before thermal runaway fully develops. This enables earlier cooling of the battery modules, helping to slow or limit thermal runaway propagation, reduce fire intensity, minimize damage, and provide valuable time for emergency response.

For these reasons, a deluge HP water mist system combined with early off-gas detection generally offers a more effective fire protection strategy than a pre-action system for lithium-ion battery applications—particularly in mission-critical facilities such as data centers.

As lithium-ion energy storage continues to expand, fire protection strategies should prioritize early detection, rapid intervention, and thermal runaway mitigation, rather than relying solely on temperature-activated discharge.

29/06/2026

🚇 The Water Mist System That Keeps the Tyne Tunnels Safe

Every year, more than 20 million vehicles travel through the Tyne Tunnel, one of the United Kingdom's most important transport links. Ensuring the safety of motorists while maintaining uninterrupted tunnel operations is a critical priority.

As part of the New Tyne Tunnels Project, High-Pressure Water Mist Fire Suppression System was designed and supplied to protect both tunnel bores.

Following comprehensive fire risk assessments, the tunnel operator selected FOGTEC's proven water mist technology to enhance:

✅ Life safety for tunnel users
✅ Rapid fire suppression and control
✅ Protection of critical tunnel infrastructure
✅ Long-term operational reliability and availability

Before commissioning, the system was successfully validated through full-scale fire testing, demonstrating its effectiveness under realistic tunnel fire scenarios.

Since entering service in 2012, the FOGTEC High-Pressure Water Mist System has been safeguarding the Tyne Tunnels for more than a decade, proving that advanced fire protection plays a vital role in ensuring both public safety and the resilience of critical transport infrastructure.

Protecting infrastructure. Safeguarding lives. Keeping essential transportation moving.

29/06/2026

🔥 The Future of Fire Protection for Lithium-Ion Battery Storage

As the adoption of lithium-ion batteries continues to grow, protecting battery storage facilities has become one of the biggest challenges in modern fire safety engineering.

Conventional sprinkler systems often struggle to control the intense heat generated during thermal runaway. In addition, the large volumes of water required can result in significant damage to equipment, inventory, and facility operations.

FOGTEC has developed a new high-pressure water mist solution specifically engineered to address the unique fire hazards associated with lithium-ion battery storage in high-bay rack warehouses.

To validate the technology, large-scale fire tests—among the most comprehensive of their kind worldwide—were successfully conducted under worst-case conditions, including:

✅ Real lithium-ion battery modules
✅ Full-scale high-bay rack storage configuration
✅ NCA and NMC battery cells charged to 100% State of Charge (SOC)
✅ Simulated thermal runaway scenario

The result?
The FOGTEC High-Pressure Water Mist System successfully contained the thermal runaway event within a single rack compartment, preventing fire propagation to adjacent storage areas.

Why is this solution different?

✔ Full-scale fire tested and independently validated under the supervision of TÜV SÜD, with testing conducted by the accredited IFAB – Institute for Applied Fire Safety Research.

✔ Up to 95% less water consumption compared with conventional rack sprinkler systems, significantly reducing water damage to surrounding equipment and stored goods.

✔ Suitable for batteries stored at up to 100% State of Charge (SOC) without operational restrictions.

As the authorized distributor of FOGTEC High-Pressure Water Mist Systems in Vietnam, TAZ Engineering Company Ltd. (TAZETCO) is ready to support consultants, developers, EPC contractors, system integrators, and facility owners with:

🔹 Engineering consultation
🔹 Fire protection system design and hydraulic calculations
🔹 Technical presentations and application studies
🔹 Supply, installation, testing, and commissioning
🔹 Inspection, maintenance, and after-sales technical support

If your organization is planning battery manufacturing plants, battery warehouses, EV production facilities, energy storage systems (BESS), or high-bay automated warehouses, we'd be pleased to discuss how this innovative solution can enhance the safety and resilience of your project.

📩 Contact TAZETCO to learn more about FOGTEC's latest lithium-ion battery fire protection technology.

TWO PROVEN SYSTEMS, DIFFERENT STRENGTHS, THE RIGHT CHOICE DEPENDS ON THE PROJECT.                                       ...
28/06/2026

TWO PROVEN SYSTEMS, DIFFERENT STRENGTHS, THE RIGHT CHOICE DEPENDS ON THE PROJECT.

Address

Toà Nhà Street Moritz. , 1014 Đ. Phạm Văn Đồng, P. Hiệp Bình
Ho Chi Minh City
70000

Opening Hours

Monday 08:00 - 17:45
Tuesday 08:00 - 17:45
Wednesday 08:00 - 17:45
Thursday 08:00 - 17:45
Friday 08:00 - 17:45

Telephone

+842836361901

Alerts

Be the first to know and let us send you an email when TAZ Engineering Company Limited posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to TAZ Engineering Company Limited:

Shortcuts

Share