This was sent to the workshop. The client said that it's not turning on. I checked the PSU board and noticed that some c...
20/08/2026

This was sent to the workshop. The client said that it's not turning on. I checked the PSU board and noticed that some components are blown but the fuse is ok. I know, I cannot outsource the transformer and based on my experience with power surge issues. Most of the time there are some other damaged components that require replacing. So I just replaced the PSu board . After replacing the PSU board. Error 8.4 appears on screen immediately indicating a damaged load cell.Good thing the client was understand the issue when I explained to him the problem.

Long story short - Issue was rectified by replacing a damaged load cell. which is probably caused by power surge .๐Ÿ’ชโ˜๏ธ

What a great feeling ending your full week of work with a great flow on your agenda. Servicing/Calibrating Seven Excelle...
08/08/2026

What a great feeling ending your full week of work with a great flow on your agenda.

Servicing/Calibrating Seven Excellence pH on our client from Monaghan. They are globally developing and manufacturing medicines, anti biotics treatment, for farm and companion animals.

Of course not everyday is like โ˜€๏ธ and ๐ŸŒน. But today, I'm just grateful for a job well done.โ˜๏ธ๐Ÿ™Œ

our aim is to give you precision results on your equipment as much as we can.

Another successful repair completed by Wishart Group Service Engineer, Fernando Perez ๐Ÿ”ง๐Ÿ’กRecently, Fernando was asked to ...
24/07/2026

Another successful repair completed by Wishart Group Service Engineer, Fernando Perez ๐Ÿ”ง๐Ÿ’ก

Recently, Fernando was asked to investigate a fingerprint comparator that was repeatedly blowing fuses, leaving the unit unusable.

The unit had previously been dismantled, with the transformer removed, leading to an initial suspicion that the transformer was at fault. However, rather than replacing expensive components, Fernando carried out a systematic fault-finding process to identify the true cause ๐Ÿ”

The culprit turned out to be the electronic dimmer, which had failed and was causing the fuses to blow.

Fernando replaced the faulty dimmer, renewed sections of the wiring, fitted a new lamp holder, and replaced three blown bulbs. Once reassembled, the illuminator was fully tested and returned to normal operation โœ…

It's another great example of why thorough diagnostics matter. By identifying the actual fault, we were able to repair the unit quickly and economically, avoiding the unnecessary replacement of a perfectly good transformer.

Excellent troubleshooting work from Fernando, getting another piece of laboratory equipment back into service ๐Ÿ‘

Stress-Relief Annealing after Laser SinteringThe combi furnace LCA 04/13 LB with annealing bell is ideal for stress-reli...
16/07/2026

Stress-Relief Annealing after Laser Sintering

The combi furnace LCA 04/13 LB with annealing bell is ideal for stress-relief annealing after laser sintering and is very easy to operate. Its compact design fits in any room, and the batch is placed under the special annealing bell. Protective gas is controlled via the integrated gas-feeding system, and the lifting table allows rapid cooling, automatically or manually.

Key features include:

โœ…Maximum working temperature: 1280 ยฐC
โœ…Protective gas options: argon (standard), optional nitrogen or forming gas, flow rate 50 โ€“ 510 l/h
โœ…Forced cooling with lifting table, fastest cooling time from 1200 ยฐC to 200 ยฐC in 100 min
โœ…Dual-sided heating with elements on support tubes for free heat radiation and long service life
โœ…Combi furnace: can also be equipped with sintering bell set for CoCr sintering

Compact, efficient, and versatile, the LCA 04/13 LB helps customers relieve stresses reliably while maintaining high-quality results.

visit at: wishartgroup.co.uk

MADE IN ITALY. ENGINEERED FOR PERFORMANCE.At Smeg Instruments, Italian manufacturing expertise meets advanced engineerin...
16/07/2026

MADE IN ITALY. ENGINEERED FOR PERFORMANCE.
At Smeg Instruments, Italian manufacturing expertise meets advanced engineering to deliver reliable, high-performance solutions for hospitals and healthcare professionals.

Designed and produced in dedicated Italian facilities, each product is developed with rigorous testing, smart resource management and intuitive operation in mind, ensuring consistent performance and long-term reliability.

From engineering excellence to dependable daily operation, we create solutions that help healthcare professionals work with confidence.
.co.uk

A busy day of fault-finding for Wishart Group Service Engineer, Fernando Perez ๐Ÿ”งโ™จ๏ธRecently, Eurofins sent us three Nicke...
25/06/2026

A busy day of fault-finding for Wishart Group Service Engineer, Fernando Perez ๐Ÿ”งโ™จ๏ธ

Recently, Eurofins sent us three Nickel-Electro Ltd. NE1-28B Boiling Baths that were all suffering from the same issue, the onboard MCB was tripping after only a few minutes of operation โš ๏ธ

These boiling baths are designed for demanding laboratory environments and, in this case, had been operating all day, every day for years. Continuous boiling naturally creates a warm, moisture-rich environment, which over time can contribute to corrosion of electrical connections.

Rather than simply replacing components, Fernando carried out a detailed inspection and quickly traced the fault to corroded spade connectors and cable terminations. The corrosion had increased electrical resistance, leading to overheating and causing the protection devices to trip ๐Ÿ”

After repairing the damaged wiring and connections, two of the boiling baths were successfully returned to full working order and passed operational testing โœ…

The third unit revealed a different issue during investigation. A micro-leak had developed in the heating element, allowing moisture to affect the electrical system. This bath will require a replacement heating element before it can be returned to service.

It's a great example of how laboratory equipment that operates continuously can eventually suffer wear-related issues, and why thorough diagnostics are so important when identifying the true cause of a fault.

Excellent troubleshooting work from Fernando, helping keep critical laboratory equipment operating safely and reliably ๐Ÿ‘

2140 vs. 0.02. The numbers speak for themselves.Why is OHAUS switching to R290 refrigerant for the Frontier 5000 Series?...
25/06/2026

2140 vs. 0.02. The numbers speak for themselves.

Why is OHAUS switching to R290 refrigerant for the Frontier 5000 Series? The math is simple, but the impact is massive.

๐“๐ก๐ž ๐†๐–๐* ๐†๐š๐ฉ:
โ€ข Old Standard (R452A): GWP โ‰ˆ 2140
โ€ข New Standard (R290): GWP โ‰ˆ 0.02

*๐˜Ž๐˜ž๐˜— (๐˜Ž๐˜ญ๐˜ฐ๐˜ฃ๐˜ข๐˜ญ ๐˜ž๐˜ข๐˜ณ๐˜ฎ๐˜ช๐˜ฏ๐˜จ ๐˜—๐˜ฐ๐˜ต๐˜ฆ๐˜ฏ๐˜ต๐˜ช๐˜ข๐˜ญ) ๐˜ช๐˜ด ๐˜ข ๐˜ฎ๐˜ฆ๐˜ข๐˜ด๐˜ถ๐˜ณ๐˜ฆ ๐˜ต๐˜ฉ๐˜ข๐˜ต ๐˜ช๐˜ฏ๐˜ฅ๐˜ช๐˜ค๐˜ข๐˜ต๐˜ฆ๐˜ด ๐˜ฉ๐˜ฐ๐˜ธ ๐˜ฎ๐˜ถ๐˜ค๐˜ฉ ๐˜ฉ๐˜ฆ๐˜ข๐˜ต ๐˜ข ๐˜จ๐˜ณ๐˜ฆ๐˜ฆ๐˜ฏ๐˜ฉ๐˜ฐ๐˜ถ๐˜ด๐˜ฆ ๐˜จ๐˜ข๐˜ด ๐˜ต๐˜ณ๐˜ข๐˜ฑ๐˜ด ๐˜ช๐˜ฏ ๐˜ต๐˜ฉ๐˜ฆ ๐˜ข๐˜ต๐˜ฎ๐˜ฐ๐˜ด๐˜ฑ๐˜ฉ๐˜ฆ๐˜ณ๐˜ฆ ๐˜ค๐˜ฐ๐˜ฎ๐˜ฑ๐˜ข๐˜ณ๐˜ฆ๐˜ฅ ๐˜ต๐˜ฐ ๐˜ค๐˜ข๐˜ณ๐˜ฃ๐˜ฐ๐˜ฏ ๐˜ฅ๐˜ช๐˜ฐ๐˜น๐˜ช๐˜ฅ๐˜ฆ (๐˜Š๐˜–โ‚‚).

That is a > 99% ๐ซ๐ž๐๐ฎ๐œ๐ญ๐ข๐จ๐ง in environmental impact. By switching to a natural refrigerant, we are helping laboratories drastically lower their carbon footprint without changing their workflow.

Same reliable OHAUS performance. Near-zero climate impact.

See the full GWP breakdown and discover what 100,000 times less climate impact truly means. https://lnkd.in/duBsn5rz


Activate to view larger image,

We're delighted to announce that Wishart Group has been granted Approved Verifier status by the Office for Product Safet...
20/06/2026

We're delighted to announce that Wishart Group has been granted Approved Verifier status by the Office for Product Safety and Standards under the Weights and Measures Act 1985. ๐ŸŽ‰โš–๏ธ

This approval allows us to test, re-qualify, and apply re-qualification marks to a range of trade-approved seca weighing instruments following repair or adjustment, providing our customers with a faster and more complete service offering.

The approval covers a number of seca โ€“ precision for health and Vogel & Halke models, including popular seca medical scales used throughout hospitals and healthcare settings.

A special thank you goes to Amanda McCarroll and Mark Henderson, who worked tirelessly through the approval process, quality system requirements, audits, and documentation needed to achieve this milestone. Their hard work and attention to detail have made this possible ๐Ÿ‘

This means that when qualifying seca scales require repair, Wishart Group can now carry out the repair, re-verify the instrument, and return it to service with minimal downtime for our customers โœ…

A fantastic achievement for the team and another step forward in expanding the services we can provide across healthcare, laboratory, and industrial weighing applications.

โš–๏ธ๐Ÿ”ง Another successful repair completed by Wishart Group engineer Rafal Orzechowski ๐Ÿ‘จโ€๐Ÿ”งA Mettler Toledo PBK989 industria...
13/06/2026

โš–๏ธ๐Ÿ”ง Another successful repair completed by Wishart Group engineer Rafal Orzechowski ๐Ÿ‘จโ€๐Ÿ”ง

A Mettler Toledo PBK989 industrial scale had suffered an overload event at Almac Group, resulting in damaged flexures and inaccurate weighing performance. โš ๏ธ๐Ÿ“ฆ

Following inspection and diagnosis, Rafal identified that the overload had caused mechanical damage to the flexure assembly, affecting the scale's ability to measure accurately.

๐Ÿ› ๏ธ Damaged flexures replaced
โš–๏ธ Scale recalibrated to specification
โœ… Performance verified through testing
๐Ÿšš Returned to site and placed back into service

By repairing the damaged components rather than replacing the entire weighing system, downtime was minimised and the customer was able to return the equipment to operation quickly and cost-effectively. ๐ŸŽฏ

At Wishart Group, our engineers provide expert diagnostics, repair and calibration services to keep critical laboratory, industrial and healthcare equipment operating accurately and reliably. ๐Ÿ’™

Well done Rafal! ๐Ÿ‘

โš–๏ธ๐Ÿ”ง๐Ÿ“

Running out of storage space is one challenge no laboratory can afford.From compact 7L benchtop units to high-capacity 8...
06/06/2026

Running out of storage space is one challenge no laboratory can afford.

From compact 7L benchtop units to high-capacity 815L upright freezers, the ARCTIKO ULUF MV range is designed to support growing storage requirements without compromising on performance.

With temperature ranges from -25ยฐC to -86ยฐC, you can protect valuable samples today while planning confidently for tomorrow.

๐Ÿ“ฆ Capacities from 7L to 815L
๐ŸŒก๏ธ Temperature ranges from -25ยฐC to -86ยฐC
๐Ÿ”ฌ Designed for laboratories, biobanks and healthcare facilities worldwide

Explore the ARCTIKO ULUF MV range via the link in the comments.

Address

10A Mill Road
Ballyclare
BT399DY

Opening Hours

Monday 9am - 5pm
Tuesday 9am - 5pm
Wednesday 9am - 5pm
Thursday 9am - 5pm
Friday 9am - 4pm

Telephone

+442893340889

Alerts

Be the first to know and let us send you an email when Wishart Group posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Business

Send a message to Wishart Group:

Shortcuts

Share