π₯ Not All Combi Boiler Swaps Are Created Equal... π₯
What looked like a simple combi-to-combi boiler replacement soon revealed a number of issues that needed putting right.
On inspection, we found:
β Existing boiler installed above a doorway with insufficient clearance
β 15mm gas pipework running all the way back to the meter, leaving it undersized for the appliance
β Condensate pipe incorrectly installed and not terminating into a suitable soakaway
β Gas pipe entering the property from the rear of the meter, which is not compliant with current standards
β Main earth bonding installed in 6mm cable and requiring an upgrade
To bring everything up to standard, we:
β
Installed the new boiler correctly with the required clearances
β
Upgraded the gas supply pipework
β
Corrected the condensate installation
β
Rectified the gas pipe entry arrangement
β
Upgraded the earth bonding from 6mm to 10mm
β
Cored a new flue position and professionally made good the old flue opening
The finished result is a safer, compliant and more reliable heating system for the customer.
πΈ Before and after photos show the full transformation.
Sometimes the biggest part of the job isn't fitting the new boilerβit's correcting the problems left behind by previous installations.
Please do get in touch if you need a new boiler installation or a full central heating system.